Aerosols 

           

 

             

   

 

 

Only  use  Antari  FLP-700  aerosol  for  the  FT-55  Fire  Training 

Fog Machine.   

 

The machine is tested and calibrated with this aerosol to get the 

best  output  performance.  Warranty  will  be  voided  if  any  other 

type  of  aerosol  is  used,  improper  use  of  aerosol  may  lead  to 

machine failure or malfunction. 

Service and Maintenance 

 

․ 

Do not allow the machine to become contaminated. 

․ 

Remove dust from air vents with air compressor, vacuum or a soft brush. 

․ 

Only use a damp cloth to clean the casing. 

․ 

Before storing run distilled water through the system to help avoid condensing the pump 

or heater. 

․ 

It is recommended to run the machine on a monthly basis in order to achieve best 

performance and output condition. 

․ 

Excessive dust, liquid and dirt built up will degrade performance and cause overheating. 

 

Breaker Reset 

 

Disconnect AC power before resetting the breaker. Only replace fuse with same 

type and rating. 

 

Step 1: Disconnect AC power. 

Step 2: Flip breaker to ON position. 

Step 3: Turn on machine for testing. 

 

Summary of Contents for FT-55

Page 1: ...1 FT 55 Fire Training Fog Machine User Manual English 2018 Antari Lighting and Effects Ltd...

Page 2: ......

Page 3: ...isconnect the machine from AC power before servicing and when not in use This product is for indoor use only Do not expose to rain or moisture If fluid is spilled disconnect AC power and clean with a...

Page 4: ...luid is swallowed immediately look for medical advice Unpacking and Inspection Immediately upon receiving the machine carefully unpack the carton check the content to ensure that all parts are present...

Page 5: ...reign objects in the threaded aerosol insert Align aerosol valve with threaded insert and carefully turn clockwise to fix into position Aerosol should be screwed in tightly to create an effective seal...

Page 6: ...ine is ready for operation Step 5 To start making fog press and hold the push button on handle bar release to stop Step 6 To adjust output volume rotate the knob located in back panel Turn counter clo...

Page 7: ...perature The amount of smoke produced depends on its temperature cycle when it is disconnected With a complete heating cycle the machine can generate smoke up to 45 minutes after disconnection The qua...

Page 8: ...vents with air compressor vacuum or a soft brush Only use a damp cloth to clean the casing Before storing run distilled water through the system to help avoid condensing the pump or heater It is recom...

Page 9: ...nge Output Control Connection Optional accessories Dimension Weight US model AC 100 120V 50 60Hz 15A EU model AC 220 240V 50 60Hz 8A 1450W 7 5 minutes approx 110 ml min Antari FLP aerosol 0 C 40 C 32...

Page 10: ......

Page 11: ......

Page 12: ...12 C08FT0551...

Reviews: