OPERATION

The DC charger is fully automatic in operation. Once installed, no further user action is 
required.  The unit automatically switches on when a charging voltage is detected on the 
input supply.  When a charging source is not present, it switches to a low power sleep mode.

SPECIFICATIONS

Model range:

Input voltage

Input current

Output voltage

Model number,

with remote sense

Model number,

no remote sense

12V

12A

12V

91136

91126

12V

15A

12V

91141

91131

12V

12A

24V

91135

91125

12V

15A

24V

91140

91130

24V

12A

12V

91138

91128

24V

15A

12V

91143

91133

24V

12A

24V

91137

91127

24V

15A

24V

91142

91132

24V

15A

24V

90131

The line charger operates in a way which controls the input current, such that the maximum 
possible power is always drawn from the power source, without overloading the input supply 
cables & connectors.  The output charging current is constrained by the ability of the source 
to supply power.  The maximum battery charging current is therefore determined by each 
particular installation.  The curves below show this dependency:
 

DC Charger User Manual, Part No. 13328 Issue 5

0

5

10

15

20

25

30

Output v oltage

0

5

10

15

20

25

30

35

O

u

tp

ut

 c

ur

re

nt

 -

 a

m

ps

Input = 25 volts
Input = 20 volts
Input = 15 volts
Input = 10 volts

Line charger  - output current vs output voltage

input voltage held constant

input current 15 amps

Summary of Contents for 91136

Page 1: ...TANT SAFETY INFORMATION INSTALLATION OPERATION Instructions for installation and use 2003 FM 37786 ISO 9002 Antares Europe Limited Chiltern Hill Chalfont St Peter Gerrards Cross Bucks SL9 9UQ UK Tel 44 0 1753 890888 Fax 44 0 1753 891260 email support antares co uk web site http www antares co uk DC Line Charger ...

Page 2: ... volt DC supply and used to charge a separate 12 or 24 volt lead acid battery Note that non vehicular marine applications are specifically excluded as the DC line charger has not been verified against the particular EMC standards that apply Non approved conditions of use This unit may be suitable for use in other applications but it can only be supplied as a component in this respect in which case...

Page 3: ... to disperse before attempting to connect this unit Before beginning the electrical installation be aware that this unit automatically switches on when a charging voltage is present on the input supply It also switches on for approximately 30 seconds when first connected to the input supply When on the output is live and capable of delivering high current so care must be exercised when making the ...

Page 4: ...spark may be seen as this connection is made which is normal and may be ignored The fourth connection is the red wire which connects directly to the positive terminal of the charging power supply A small spark may be seen as this connection is made which is normal and may be ignored The remote battery sensor if used should be attached to the battery to be charged then plugged into the line charger...

Page 5: ...2A 24V 91137 91127 24V 15A 24V 91142 91132 24V 15A 24V 90131 The line charger operates in a way which controls the input current such that the maximum possible power is always drawn from the power source without overloading the input supply cables connectors The output charging current is constrained by the ability of the source to supply power The maximum battery charging current is therefore det...

Page 6: ...table below lists the maximum total output cable length positive plus negative for various cable sizes when remote sense is not used Cable size Maximum length 0 1volt drop 2 5mm2 1 4 metres 4mm2 2 3 metres 6mm2 3 4 metres 10mm2 5 9 metres Suzi connector The line charger may be used through the 12N S or 24N S trailer sockets to charge a trailer battery The line charger is mounted on the trailer nea...

Reviews: