background image

Antaira Technologies - Industrial Ethernet Switches
LMX-1802G-M12-10G-SFP-67 Series - Hardware Manual - v1.0

3 Mounting Installation

3.1 Wall Mounting

Follow the steps below to mount the industrial Ethernet switch to a wall using the screw holes as shown below in Figure

3.1.

Figure 3.1 - The Rear Side of the Switch

Follow the steps below to learn how to hang the industrial Switch.

Step 1. Prepare 4 screws for mounting the switch to a wall.

Note: Recommended use of the M5 screws.

Step 2. Based on the Figure 2.1: Physical Dimensions which is shown the positions of 4 screw holes on the left and right

side of the switch to make 4 screw holes on a wall accordingly.

Step 3. Insert the screws through the screw holes on the switch and screw the switch into the wall. Shown above in Figure

3.1.

Step 4. To remove the switch from the wall, do the opposite from the steps above.

Note: Make sure to disconnect all cables from the switch before removing the unit from the wall.

15

Summary of Contents for LMX-1802G-M12-10G-SFP-67 Series

Page 1: ...7 Series 18 Port Industrial M12 IP67 Waterproof Gigabit Light Layer 3 Managed Ethernet Switch with 16 10 100 1000Tx M12 Connectors X Coded and 2 1G 10G SFP Ports 24 55VDC Power Input Hardware Manual Version 1 0 November 2021 ...

Page 2: ...ions of the product described in this manual without prior notice Antaira Technologies LLC will not be liable for any technical inaccuracies or typographical errors found in this guide Changes are periodically made to the information contained herein and will be incorporated into later versions of the manual The information contained is subject to change without prior notice FCC Warning This equip...

Page 3: ...rences nuisibles à la réception radio ou télévision ce qui peut être déterminé en éteignant puis en rallumant l équipement l utilisateur est encouragé à essayer de corriger les interférences par une ou plusieurs des mesures suivantes Réorientez ou déplacez l antenne de réception Augmentez la distance entre l équipement et le récepteur Connectez l équipement à une prise sur un circuit différent de ...

Page 4: ...ernet Switches LMX 1802G M12 10G SFP 67 Series Hardware Manual v1 0 This document is the current official release hardware manual Please check our website www antaira com for any updated manual or contact us by e mail support antaira com ...

Page 5: ...Physical Dimensions 4 2 2 Front View Panel 5 2 3 Top View Panel 5 2 4 LED Indicators 6 2 5 Reset to Default 7 2 6 Ethernet Ports 7 2 7 Fiber Port 9 2 8 USB Port 10 2 9 Console Port 10 2 10 Power Inputs 11 2 11 Relay Contact and Digital Input 11 2 12 Grounding Note 13 2 13 Bypass Function 14 3 Mounting Installation 15 3 1 Wall Mounting 15 4 Hardware Installation 17 4 1 Installation Steps 17 4 2 Mai...

Page 6: ...hernet switch that meets the high reliability requirements demanded by industrial applications Its M12 connectors ensure a tight and robust connection and it guarantees reliable operation on applications that are subject to high vibration and shock in dust liquid or gas laden environments Being able to operate under the standard temperature range from 10 C to 65 C or the extended temperature range...

Page 7: ...ent syslog Event Handling Event notification Cold Warm Start Power Failure Authentication SNMP trap and Fault Alarm Relay Output Storage Upgrade via TFTP and HTTP Configuration Backup USB Port 1 3 Package Contents LMX 1802G M12 10G SFP 67 T Quick Installation Guide 2 SFP metal field installable cable end lock Dust cover set SFP removal kit 1 4 Safety Precaution Attention If the DC voltage is suppl...

Page 8: ...when working with the device Shown in Figure 1 1 Étiquettes d avertissement L étiquette d avertissement signifie que vous devez vérifier certaines informations du manuel d utilisation lorsque vous travaillez avec l appareil Illustré à la figure 1 1 Figure 1 1 Caution Label Figure 1 1 Étiquette de mise en garde Figure 1 2 Hot Surface Warning Label Figure 1 2 Étiquette d avertissement de surface cha...

Page 9: ...tches LMX 1802G M12 10G SFP 67 Series Hardware Manual v1 0 2 Hardware Description 2 1 Physical Dimensions Figure 2 1 below shows the physical dimensions of this product series W x D x H is 183mm x 295mm x 101 3mm Figure 2 1 Physical Dimensions 4 ...

Page 10: ...G M12 10G SFP 67 Series Hardware Manual v1 0 2 2 Front View Panel Figure 2 2 below shows the front panel of the product series Figure 2 2 Front View Panel 2 3 Top View Panel Figure 2 3 below shows the top panel of the product series Figure 2 3 Top View Panel 5 ...

Page 11: ...ystem is ready and works fine There are no events occurring Red Flashing Firmware upgrading On System booting or configured event happens Master Green On ERPS Owner Mode Ring Master is ready Off ERPS Owner Mode is not active Ring Green On Ring Network is active Flashing ERPS Ring works abnormally or misconfigured Off Ring Network is not active LAN Port 1 16 Green On Connected to network 1000Mbps F...

Page 12: ...n the process is completed Step 5 Remove the reversed console cable 2 6 Ethernet Ports M12 Interface Auto MDI MDI X Connection Format M12 8 Pin X Coded Female Connector Transmission rate 10 100 1000Mbps Prepare the M12 8 Pin X Coded Ethernet Port mating cable for Ethernet connection The M12 X Coded Ethernet ports are auto sensing for 10Base T 100Base TX or 1000Base T devices connections Auto MDI M...

Page 13: ...d the link partner switch hub workstation etc must be less than 100 meters 328 ft long Minimum Wire Gauge 24AWG Maximum Transmission Length 100m 328ft Caution Please use copper conductors only Attention Veuillez utiliser uniquement des conducteurs en cuivre Caution Use conductors with insulation rated for at least 60 C Attention Utilisez des conducteurs dont l isolation est d au moins 60 C Caution...

Page 14: ...iber port 1 Pull out the SFP module which needs to be replaced 2 Put the fiber cable through the metal end lock sealing and cap 3 Insert the SFP transceiver into the Metal Panel Lock and tighten and seal all parts Figure 2 4 SFP module installation Caution Please employ an optional optical transceiver SFP that complies with IEC 60825 1 and is classified as Class 1 laser product Attention Veuillez ...

Page 15: ...t is for configuration backup restore M12 connector M12 4 Pin A Coded female connector Pinouts Function 1 DN 2 VBUS 3 GND 4 DP Table 2 3 USB port pinouts 2 9 Console Port It is an M12 5 Pin A Coded female connector Baud rate 115 200bps 8 N 1 M12 connector M12 5 Pin A Coded female connector Pinouts Function 1 NC 2 TX 3 RX 4 NC 5 GND Table 2 4 Console port pinouts 10 ...

Page 16: ...he steps below to insert the power wire Step 1 Insert the positive and negative power wires into the power connector on the industrial Ethernet switch with Power 1 V1 V1 and Power 2 V2 V2 Step 2 Tighten the screw nut to prevent the connector from loosening 2 11 Relay Contact and Digital Input The Ethernet switch is equipped with an M12 5 Pin A Coded Male connector with a normally closed relay cont...

Page 17: ...e conditions below 1 No event after reboot 2 No event after reset the switch A connection of relay contact for fault alarm is shown below in Figure 2 5 Figure 2 5 Wiring the relay contact for fault alarm When the Ethernet switch is operating normally the relay contact is a closed circuit When the switch has any fault status PoE overload or power failure the relay contact circuit is opened and the ...

Page 18: ...t current 8mA Table 2 7 Specification of DI As described in the Relay Contact section if the fault status total output power over device s PoE power budget or any one of PoE ports over 30 Watts happens you have to use DI function to reset the Fault LED so there are two DI functions this unit supports for manually reset or reboot the device which is shown as follows 1 When the trigger time 4 second...

Page 19: ...itches loses power Ethernet ports P8 and P16 will bypass the power lost Ethernet switch to prevent the network from disconnecting Take Figure 2 7 for example if Switch B has power failure the bypass function will be activated automatically and it will bypass Switch B and bridge P8 to P16 of Switch B so that the data transmission path from Switch A to C can remain connected and unaffected Figure 2 ...

Page 20: ...tep 1 Prepare 4 screws for mounting the switch to a wall Note Recommended use of the M5 screws Step 2 Based on the Figure 2 1 Physical Dimensions which is shown the positions of 4 screw holes on the left and right side of the switch to make 4 screw holes on a wall accordingly Step 3 Insert the screws through the screw holes on the switch and screw the switch into the wall Shown above in Figure 3 1...

Page 21: ...Antaira Technologies Industrial Ethernet Switches LMX 1802G M12 10G SFP 67 Series Hardware Manual v1 0 Figure 3 2 Position of the screw holes 16 ...

Page 22: ...ing box 2 To hang the industrial Ethernet switch on a wall please refer to the Mounting Installation section 3 Power on the industrial Ethernet switch and then the power LED light will turn on If you need help on how to wire power please refer to the Power Inputs section Please refer to the LED Indicators section for LED light indication 4 Prepare the M12 cable for Ethernet connection 5 Insert one...

Page 23: ...d or follow the instructions within the manual Clean the device with dry soft cloth 4 3 Troubleshooting Always verify the right power cord or adapter is being used Never use a power supply or adapter with a non compliant DC output voltage or it will burn the equipment Diagnosing LED Indicators To assist in identifying problems the switch can be easily monitored with the LED indicators which help t...

Page 24: ... policer Port egress shaper Queue egress shaper DiffServ DSCP Tag remarking Scheduler mode Power Saving ActiPHY PerfectReach IEEE 802 3az EEE power management Network Redundancy STP RSTP MSTP port trunk with LACP ERPS v1 v2 50ms Configuration Http Https Telnet SSH CLI TFTP SNMP v3 System Diagnostics Dual Image Protection PING PING6 Switch Properties Switch Architecture Back Plane Switching Fabric ...

Page 25: ...atus Ethernet ports Speed Link Active SFP Link Active Protection Network Cable 10Base T 2 pair UTP STP Cat 3 4 5 cable EIA TIA 568 100 ohm 100m 100Base TX 2 pair 2 pair UTP STP Cat 5 cable EIA TIA 568 100 ohm 100m 1000BaseTX 4 pair UTP STP Cat 5 5E cable EIA TIA 568 100 ohm 100m Optical Cable Multi mode cable 50 125um or 62 5 125um Single mode cable 9 125um or 10 125um Mechanical Characteristics H...

Page 26: ... 2 EN61000 4 2 3 4 5 6 8 Free Fall IEC60068 2 32 Shock IEC60068 2 27 Vibration IEC60068 2 6 Green RoHS Compliant Certifications FCC CE Warranty 5 Years Table 5 1 Technical Specifications Antaira Customer Service and Support Antaira US Headquarter 844 268 2472 Antaira Europe Office 48 22 862 88 81 Antaira Asia Office 886 2 2218 9733 Please report any problems to Antaira www antaira com support anta...

Reviews: