2.6 Ethernet Ports 

 

 

RJ-45 Ports

RJ-45  Ports  (Auto  MDI/MDIX):  The  RJ-45  ports  are  auto-sensing for 10Base-T  or 100Base- 

TX  connections.  Auto  MDI/MDIX  means  that  the  switch  can  connect  to  another  switch  or 

workstation without  changing the straight-through or crossover cabling. See the figures below 

for straight-through and crossover cabling schematics. 

 

 

RJ-45 Pin Assignments

 

Pin Number 

Assignment 

Rx+ 

Rx- 

Tx+ 

Tx- 

Table 2.3 - RJ45 Pin Assignments 

 

Note: 

The “+” and “-” signs represent the polarity of the wires that make up each wire pair. 

 

 

All ports on this industrial Ethernet switch support automatic MDI/MDI-X operations. Users can 

use straight-through cables (see figure below) for all network connections to PCs, servers, and 

other switches or hubs. With straight-through cabling, pins 1, 2, 3, and 6 are at one end of the 

cable  and  are  connected  straight  through  to  pins  1,  2,  3  and  6  at  the  other  end  of  the  cable.  

The table below (Table 2.3) shows the 10BASE-T/100BASE-TX MDI and MDI-X port pin outs. 

 

 

Pin MDI-X 

Signal Name 

MDI Signal Name 

Receive Data plus (RD+) 

Transmit Data plus (TD+) 

Receive Data minus (RD-) 

Transmit Data minus (TD-) 

Transmit Data plus (TD+) 

Receive Data plus (RD+) 

Transmit Data minus (TD-) 

Receive Data minus (RD-) 

Table 2.4 - Ethernet Signal Pin 

Summary of Contents for LMX-0800 Series

Page 1: ...Antaira Industrial Ethernet Switches LMX 1002C SFPeries User Manual V1 0 i LMX 0800 Series 8 Port Industrial Managed Ethernet Switches With 8 10 100Tx Ethernet Ports Version 1 3 Hardware Manual...

Page 2: ...Notice Copyrights 2018 by Antaira Technologies LLC All rights reserved Reproduction adaptation or translation without prior permission of Antaira Technologies LLC is prohibited except as allowed unde...

Page 3: ...ouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the eq...

Page 4: ...recaution 3 2 Hardware Description 4 2 1 Physical Dimensions 4 2 2 Front Panel 5 2 3 Top View 5 2 4 LED Indicators 6 2 5 Reset Button 6 2 6 Ethernet Ports 7 2 7 Cabling 8 2 8 Wiring the Power Inputs 8...

Page 5: ...S SNMP RMON Modbus TCP and 802 1X HTTPS SSH SSL increase determinism and improve network management for remote SCADA systems or control networks The LMX 0800 series is compact IP30 rated and DIN rail...

Page 6: ...ion Embedded 8 10 100Tx Fast Ethernet RJ45 Ports Store and forward switching architecture 8K MAC address table Power line EFT protection 2 000VDC Ethernet ESD protection 6 000VDC Power Input DC 12 48V...

Page 7: ...If the DC voltage is supplied by an external circuit please use a protection device on the power supply input The industrial Ethernet switch s hardware specs ports cabling information and wiring inst...

Page 8: ...anual V1 3 2 Hardware Description 2 1 Physical Dimensions Figure 2 1 below shows the physical dimensions of Antaira s LMX 0800 series 8 port industrial managed Ethernet switches with 8 10 100Tx ports...

Page 9: ...t Grounding Screw LED for PWR1 PWR2 and Fault LAN Port 5 8 10 100Tx Hard Physical Reset Button Console Port USB Backup LAN Port 1 4 10 100Tx LED for 10 100Tx network speed Status The Front Panel of LM...

Page 10: ...ve port alarm is disabled Owner Green On ERPS Owner Mode Ring Master is ready Off ERPS Owner Mode is not active Ring Green On Ring Network is active Off Ring Network is not active LAN Port 1 8 Left LE...

Page 11: ...the polarity of the wires that make up each wire pair All ports on this industrial Ethernet switch support automatic MDI MDI X operations Users can use straight through cables see figure below for all...

Page 12: ...er switch hub workstation etc must be less than 100 meters 328 ft in length 2 8 Wiring the Power Inputs Caution Please follow the steps below when inserting the power wire 1 Insert the positive and ne...

Page 13: ...rm contact is shown below in Figure 2 8 Caution The wire gauge for the terminal block should range between 12 24AWG If only using one power source jumper Pin 1 to Pin 5 and Pin 2 to Pin 6 to eliminate...

Page 14: ...to install the DIN Rail bracket on the rear side of the industrialEthernet switch Caution The torque for tightening the screws on the device is 3 5 in lbs 2 To remove the DIN Rail bracket do the oppo...

Page 15: ...l mounting brackets on the top and bottom of the industrial Ethernet switch 3 Use the screws to screw the wall mounting bracket on the industrial Ethernet switch Caution The torque for tightening the...

Page 16: ...rial Ethernet switch on a DIN Rail or wall please refer to the Mounting Installation section 4 Power on the industrial Ethernet switch and then the power LED light will turn on If you need help on how...

Page 17: ...ches with 8 10 100Tx ports Standards IEEE 802 3 10Base T 10Mbit s Ethernet IEEE 802 3u 100Base Tx Fast Ethernet IEEE 802 3x Flow Control for Full Duplex IEEE 802 3ad Port Trunking with LACP IEEE 802 1...

Page 18: ...ounting DIN Rail Mounting wall mounting optional Power Requirement Input Voltage 12 48VDC Redundant Input Power Connection 1 removable 6 contact terminal block Power Consumption 15 Watts Environmental...

Reviews: