background image

Antaira Technologies - Industrial Ethernet Switches 

LMP-1204G-SFP Hardware Manual V1.3 

 

 

 

2. Hardware Description 

2.1 Physical Dimensions 

Figure 2.1

, below, shows the physical dimensions of Antaira’s LMP-1204G-SFP series: 12-port 

industrial gigabit PoE+ managed Ethernet switches with 8*10/100/1000Tx ports and 

4*100/1000Fx SFP slots. 

 

(W x D x H) is 

54mm x 99mm x 142mm 

 

 

 

 

Figure 2.1 

LMP-1204G-SFP Series Physical Dimensions 

Summary of Contents for LMP-1204G-SFP Series

Page 1: ...s LMP 1204G SFP Series User Manual V2 1 i LMP 1204G SFP Series LMP 1204G SFP LMP 1204G SFP T 12 Port Industrial PoE Gigabit Managed Ethernet Switch with 8 10 100 1000Tx 30W Port and 4 100 1000 SFP Slots Hardware Manual Version 1 3 P N 92001204480201 ...

Page 2: ... Notice Copyrights 2018 by Antaira Technologies LLC All rights reserved Reproduction adaptation or translation without prior permission of Antaira Technologies LLC is prohibited except as allowed under the copyright laws Disclaimer Antaira Technologies LLC provides this manual without warranty of any kind expressed or implied including but not limited to the implied warranties of merchantability a...

Page 3: ...n be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio...

Page 4: ... only be used in an area of not more than pollution degree 2 as defined in EN 60664 1 Provisions shall be made to prevent the rated voltage from being exceeded by transient disturbances of more than 140 Conductors suitable for use in an ambient temperature of 105 7 C must be used for the Power Supply Terminal The external grounding conduct shall be at least 4 mm2 WARNING EXPLOSION HAZARD Do not di...

Page 5: ...ecaution 3 2 Hardware Description 4 2 1 Physical Dimensions 4 2 2 Front Panel 5 2 3 Top View 5 2 4 LED Indicators 6 2 5 Reset Button 7 2 6 Ethernet Ports 7 2 7 Cabling 8 2 8 Wiring the Power Inputs 8 2 9 Wiring the Fault Alarm Contact 9 2 10 Grounding Note 9 3 Mounting Installation 10 3 1 DIN Rail Mounting 10 3 2 Wall Mounting 11 4 Hardware Installation 12 4 1 Installation Steps 12 4 2 Maintenance...

Page 6: ...032 ERPS Ethernet Ring Protection Switch protocol that has a 50ms network recovery time The advanced network filtering and security functions such as IGMP VLAN QoS SNMP RMON Modbus TCP and 802 1X HTTPS SSH SSL increase determinism and improve network management for remote SCADA systems or control networks The LMP 1204G SFP series is IP30 rated and DIN rail mountable There are also two wide operati...

Page 7: ...rface and Performance All RJ 45 ports support Auto MDI Function Embedded 8 10 100 1000Tx PSE 30W Port RJ45 Ports and 4 100 1000 SFP slots for fiber Store and forward switching architecture 8K MAC address table Power line EFT protection 2 000VDC Ethernet ESD protection 6 000VDC Power Input DC 48 55V 5 5A redundant with a 6 pin removal terminal block One user programmable alarm relay contact 24 VDC ...

Page 8: ...Safety Precaution Attention If the DC voltage is supplied by an external circuit please use a protection device on the power supply input The industrial Ethernet switch s hardware specs ports cabling information and wiring installation will be described within this user manual Warning Labels The caution label means that you should check the certain information on user manual when working with the ...

Page 9: ...tion 2 1 Physical Dimensions Figure 2 1 below shows the physical dimensions of Antaira s LMP 1204G SFP series 12 port industrial gigabit PoE managed Ethernet switches with 8 10 100 1000Tx ports and 4 100 1000Fx SFP slots W x D x H is 54mm x 99mm x 142mm Figure 2 1 LMP 1204G SFP Series Physical Dimensions ...

Page 10: ...D for PWR1 PWR2 and Fault LAN Port 9 12 100 1000 SFP Slots Console Port USB Backup Hard Physical Reset Button LAN Port 1 8 10 100 1000Tx LED for 10 100 1000Tx Network Speed Status LED for PoE Activity Figure2 2 The Front Panel of LMP 1204G SFP Series 2 3 Top View Figure 2 3 below shows the top panel of the LMP 1204G SFP series switch that is equipped with one 6 pin removal terminal block connector...

Page 11: ...ional and no active port alarm is detecting errors Owner Green On ERPS Owner Mode Ring Master is ready Off ERPS Owner Mode is not active Ring Green On Ring Network is active Off Ring Network is not active LAN Port 9 12 Link ACT SFP Port Green On Connected to Network 1000Mbps Flashing Network is active Off Not connected to network Amber On Connected to network 100Mbps Flashing Network is active Off...

Page 12: ...ons Auto MDI means that the switch can connect to another switch or workstation without changing the straight through or crossover cabling See the figures below for straight through and crossover cabling schematics RJ 45 Pin Assignments Pin Number Assignment 1 Rx 2 Rx 3 Tx 6 Tx Table 2 3 RJ45 Pin Assignments Note The and signs represent the polarity of the wires that make up each wire pair All por...

Page 13: ...matic Figure 2 5 Crossover Cable Schematic 2 7 Cabling Use the four twisted pair category 5e or the above cabling for the RJ 45 port connections The cable between the switch and the link partner switch hub workstation etc must be less than 100 meters 328 ft in length 2 8 Wiring the Power Inputs Please follow the steps below when inserting the power wire 1 Insert the positive and negative wires int...

Page 14: ...managed industrial switch only and forma normally open circuit An application example for the fault alarm contact is shown below in Figure 2 8 Caution The wire gauge for the terminal block should range between 12 24AWG If only using one power source jumper Pin 1 to Pin 5 and Pin 2 to Pin 6 to eliminate power fault alarm 2 10 Grounding Note Grounding and wire routing help limit the effects of noise...

Page 15: ...of the industrial Ethernet switch Caution The torque for tightening the screws on the device is 3 5 in lbs 2 To remove the DIN Rail bracket do the opposite from step 1 3 After the DIN Rail bracket is installed on the rear side of the switch insert the top of the DIN Rail on to the track as shown below in Figure 3 2 4 Lightly pull down the bracket on to the rail as shown below in Figure 3 3 5 Check...

Page 16: ... mounting brackets on the top and bottom of the industrial Ethernet switch 3 Use the screws to screw the wall mounting bracket on the industrial Ethernet switch Caution The torque for tightening the screws on the device is 3 5 in lbs 4 Use the hook holes at the corners of the wall mounting bracket to hang the industrial Ethernet switch on the wall 5 To remove the wall mount bracket do the opposite...

Page 17: ...on If you want to wall mount the industrial Ethernet switch please refer to the Wall Mounting section for wall mounting installation 3 To hang the industrial Ethernet switch on a DIN Rail or wall please refer to the Mounting Installation section 4 Power on the industrial Ethernet switch and then the power LED light will turn on If you need help on how to wire power please refer to the Wiring the P...

Page 18: ... soft cloth 5 Technical Specifications Table 5 1 has the technical specifications for Antaira s LMP 1204G SFP series 12 port industrial gigabit PoE managed Ethernet switch with 8 10 100 1000Tx PSE 30W Port and 4 100 1000 SFP slots Standards IEEE 802 3 10Base T 10Mbit s Ethernet IEEE 802 3u 100Base Tx 100Base Fx Fast Ethernet IEEE 802 3ab 1000Base Tx Gigabit Ethernet IEEE 802 3z Gigabit Fiber IEEE ...

Page 19: ...ackup Port 1 USB 2 0 Protection Overload Current Present Power Reverse polarity Present CPU Watch Dog Present Network Cable 10Base T 2 pair UTP STP Cat 3 4 5 cable 100Base TX 2 pair UTP STP Cat 5 cable EIA TIA 568 100 ohm 100m 1000BaseTX UTP STP Cat 5 5E cable EIA TIA 568100 ohm 100m Mechanical Characteristics LED Indicator Power Unit P1 Green P2 Green fault Green Red Ethernet port Link active Gre...

Page 20: ... Certifications NEMA TS2 Table 5 1 LMP 1204G SFP Series Technical Specifications Antaira Customer Service and Support Antaira US Headquarter 844 268 2472 Antaira Europe Office 48 22 862 88 81 Antaira Asia Office 886 2 2218 9733 Please report any problems to Antaira www antaira com support antaira com www antaira eu info antaira eu www antaira com tw info antaira com tw Any changes to this material...

Reviews: