The following figures show the cabling schematics for straight-through and crossover.
2.7 Cabling
Use the four twisted-pair, category 5e, or the above cabling for the RJ-45 port connections. The
cable between the switch and the link partner (switch, hub, workstation, etc.) must be less than 100
meters (328 ft.) in length.
2.8 Wiring the Power Inputs
Please follow the steps below when inserting the power wire.
1. Insert the positive and negative wires into the PWR1 (V1+, V1-) and PWR2 (V2+, V2-) contacts
on the terminal block connector as shown below in
Figure 2.6
.
2. Tighten the wire-clamp screws to prevent the wires from loosening, as shown below in
Figure 2.7
.
Note:
Only use copper conductors,
60/75
°
C
, tighten to
5lbs.
The wire gauge for the terminal block should range between
18~20 AWG
.
Figure 2.7 - Power Terminal Block
Figure 2.6 - Power Terminal Block
Figure 2.4
Figure 2.5
Straight-Through Cable Schematic
Crossover Cable Schematic