Antaira Industrial Ethernet Switches
LMX-0500 Series User Manual V1.1
7
2.6 Cabling
Twisted-pair segments can be connected with an unshielded twisted pair (UTP) or shielded
twisted pair (STP) cable. The cable must comply with the IEEE 802.3u 100Base TX
standard (e.g. Category 5, 5e, or 6). The cable between the equipment and the link partner
(switch, hub, workstation, etc.) must be less than 100 meters (328 ft.) long.
2.7 Wiring the Power Inputs
Please follow below steps to insert the power wire.
1. Insert the positive and negative wires into the PWR1 (V1+, V1-) and PWR2 (V2+, V2-)
contacts on the terminal block connector as shown below in Figure 2.6.
2. Tighten the wire-clamp screws to prevent the wires from loosening, as shown below in Figure
2.7.
Note
Only use copper conductors, 60/75°C, tighten to 5lbs.
The wire gauge for the terminal block should range between 18~20 AWG.
Figure 2.7 - Power Terminal Block
Figure 2.6 - Power Terminal Block