EN
18
SYMBOLS
Read the instructions.
Safety class II.
Approved in accordance with the
relevant directives.
Recycle discarded product as electri-
cal waste.
TECHNICAL DATA
Rated voltage
230 V ~ 50 Hz
Cord length
160 cm
Service value (SV)
1.59 (m3/min)/W
Output 60 W
Power consumption
in standby mode (Psb)
0.349 W
maximum air velocity (c)
3.28 m/s
Seasonal electricity consumption(Q) 18.70 kWh/a
Fan power input(P)
57.23 W
Sound power level (Lwa)
65.6 dB(A)
Max fan flow rate(F)
91.23 m3/min
Operating value standard
IEC 60879:1986
(corr. 1992)
Protection rating
IPX0
Safety class
II
Size
470x1230x130xØ400 mm
DESCRIPTION
1.
Front grille
2. Dome nut
3. Fan blade
4. Lock nut for rear grille
5. Rear grille
6. Motor unit
7. Motor casing
8. Bracket
9. Electrical box
10. Locking screw A
11. Power cord
12. Top tube
13. Locking screw B
14. Main tube
15. Base plate
16. Base nut
17. Remote control
18. Locking screw for grille
19. Oscillation button
FIG. 1
ASSEMBLY
1. Loosen the lock nut (16) from the main
tube (14) and insert the main tube (14)
into the base plate (15). Tighten the base
nut (16).
2. Unscrew the locking screw B (13) and
adjust to an appropriate height. Tighten
the locking screw B (13).
3. Fit the junction box (9) on the upper tube
(12) and tighten the locking screw A (10).
4. Loosen the lock nut (4) for the back grille
from the motor unit (6) and fit the back
grille (5) on the motor unit (6) by aligning
the three pins. Refit and tighten the lock
nut (4).
5. Fit the fan blade (3) on the motor shaft
and lock with the dome nut (2).
6. Position the front grille (1) against the
back grille (5), align and lock the clamp
and tighten the grille locking screw (18).