Section 3 Operation
3-66
(2)
Measurement procedure
Step
Operation procedure
1
Press the spectrum analyzer [Preset] key.
2
Span frequency setting: F2: Span , [8], [0], [0], [kHz]
3
Reference level setting: F3: Amplitude , [0], [dBm]
4
Center frequency setting: F1: Frequency , [1], [.], [9], [GHz]
5
RBW setting: [Next Menu], F1: Coupled Function , F7: RBW, [1], [kHz]
6
VBW setting: F12: return, F8: VBW, [1], [kHz]
7
Sweep time setting: F12: return, F9: Sweep Time, [3], [s]
8
Single sweep: [Single]
9
Measurement preparations: Select F5: Measure , F9: Occ BW Measure, F11, Setup, F7: Method, and
N% of PWR.
F8: N%Ratio, [9], [9], [Enter]
10
Power (noise) measurement: F12: return, F7: Execute
The measured value is displayed at the top left-hand corner of the screen.
★
Example of measured result: Occ BW: 240 kHz, CTR; 1.9000000 GHz
★
Application: Occupied frequency bandwidth (PDC, PHS, etc.)
Zone Center =
500.008 000MH
Occupied frequency bandwidth measurement example