Anritsu MP1590B-30 Operation Manual Download Page 3

 

iii 

Equipment Certificate 

Anritsu Corporation certifies that this equipment was tested before 
shipment using calibrated measuring instruments with direct traceabil-
ity to public testing organizations recognized by national research labo-
ratories including the National Institute of Advanced Industrial Science 
and Technology, and the National Institute of Information and Commu-
nications Technology, and was found to meet the published specifica-
tions. 
 
 

Anritsu Warranty 

Anritsu Corporation will repair this equipment free-of-charge if a mal-
function occurs within 1 year after shipment due to a manufacturing 
fault, provided that this warranty is rendered void under any or all of the 
following conditions. 
 

  The fault is outside the scope of the warranty conditions described in 

the operation manual. 

  The fault is due to mishandling, misuse, or unauthorized modification 

or repair of the equipment by the customer. 

  The fault is due to severe usage clearly exceeding normal usage. 

  The fault is due to improper or insufficient maintenance by the cus-

tomer. 

  The fault is due to natural disaster including fire, flooding, earth-

quake, etc. 

  The fault is due to use of non-specified peripheral equipment, periph-

eral parts, consumables, etc. 

  The fault is due to use of a non-specified power supply or in a 

non-specified installation location. 

 
In addition, this warranty is valid only for the original equipment pur-
chaser.    It is not transferable if the equipment is resold. 
 
Anritsu Corporation shall assume no liability for injury or financial loss of 
the customer due to the use of or a failure to be able to use this equipment. 
 
 

Anritsu Corporation Contact 

In the event that this equipment malfunctions, contact an Anritsu Ser-
vice and Sales office.    Contact information can be found on the last page 
of the printed version of this manual, and is available in a separate file 
on the CD version. 

Summary of Contents for MP1590B-30

Page 1: ...ead this manual before attempting to use the equipment Additional safety and warning information is pro vided within the MP1590B Network Performance Tester Operation Manual Please also refer to this d...

Page 2: ...Used on Equipment and in Manual The following safety symbols are used inside or on the equipment near operation locations to provide information about safety items and operation precautions Insure th...

Page 3: ...se or unauthorized modification or repair of the equipment by the customer The fault is due to severe usage clearly exceeding normal usage The fault is due to improper or insufficient maintenance by t...

Page 4: ...s country of origin for re export from your country Before re exporting the product or manuals please contact us to confirm whether they are export controlled items or not When you dispose of export...

Page 5: ...g 1 Product Model Option MP1590B 30 High Precision Jitter Analysis 2 Applied Directive and Standards When the MP1590B 30 High Precision Jitter Analysis are installed in the MP1590B the applied directi...

Page 6: ...Model Option MP1590B 30 High Precision Jitter Analysis 2 Applied Directive and Standards When the MP1590B 30 High Precision Jitter Analysis are installed in the MP1590B the applied directive and stand...

Page 7: ...Unit Rx Narrow MU150123A 10 10 7G Optical Unit Rx Wide MU150134A 10 10 7G Optical Unit Tx Ex Mod Operation Manual Explains specification for EO OE module Shows this document Explains specification for...

Page 8: ...Operation Manual Explains specification for MP1590B 30 MP1590B 30 High Precision Jitter Analysis Operation Manual Explains operation for the software that monitors traffics on Ethernet Application Tr...

Page 9: ...III This Operation Manual supports MP1590B 30 High Precision Jitter Analysis for MP1590B It is explained in the text in the case of MP1590B 30 High Precision Jit ter Analysis...

Page 10: ...This Manual I Chapter 1 Overview 1 1 1 1 Overview 1 2 1 2 O 172 New Recommendation and Verification Method for Jitter Measurement Accuracy 1 2 1 3 Product Configuration 1 3 Chapter 2 Specifications 2...

Page 11: ...des an overview and describes the product configura tion of the MP1590B 30 High Precision Jitter Analysis 1 1 Overview 1 2 1 2 O 172 New Recommendation and Verification Method for Jitter Measurement A...

Page 12: ...was adopted in the ITU T O 172 April 2005 Therefore this method is Global Standard of the Jitter measurement in strument 1 2 O 172 New Recommendation Verification Method for Jitter Measurement Accura...

Page 13: ...on Verification Method for Jitter Measurement Accuracy Ch4 Reference clock Ch3 Optical data Data Trigger Pattern sync signal O 172 Phase Analysis Method Clock DUT Sampling oscilloscope Pulse pattern g...

Page 14: ...Main Frame MU150100A 10 10 7 G unit MU150110A Multirate unit 2 MU150134A 10 10 7 G Optical unit Tx Ex Mod MU150123A 10 10 7 G Optical unit Rx wide MU150123B 10 10 7 G Optical Electrical unit Rx wide...

Page 15: ...Chapter 2 Specifications 2 1 This chapter provides the specifications of the MP1590B 30 High Preci sion Jitter Analysis 2 1 Specifications 2 2...

Page 16: ...ement conditions Measurement time 1 min Average 5 measurements Filter 10 G 20 kHz to 80 MHz 50 kHz to 80 MHz 2 5 G 5 kHz to 20 MHz 12 kHz to 20 MHz Transmitter MU150121A B MU150134A or an optical tran...

Page 17: ...as a reference value for the meas urement accuracy Item 1 2 2 Measurement conditions Filter 10 G 20 kHz to 80 MHz 50 kHz to 80 MHz 2 5 G 5 kHz to 20 MHz 12 kHz to 20 MHz Pattern OC 192c STM 64c J0 Z0...

Page 18: ...asurement time 1 min Filter 10 G 20 kHz to 80 MHz 50 kHz to 80 MHz 4 MHz to 80 MHz 2 5 G 5 kHz to 20 MHz 12 kHz to 20 MHz 1 MHz to 20 MHz Pattern OC 192c STM 64c OC 48c STM 16c Payload PRBS23 31 Optic...