Anritsu MN25131A Series Operation Manual Download Page 5

MN25131A OM

PN: 10410-00783  Rev. A

1-1

Chapter 1 — Introduction

The MN25131A Multi-Function Extender provides USB hub and communication extension, multiple voltage 
outputs, and battery power capabilities to enable remote use of USB instruments. USB to SFP (small 
form-factor pluggable fiber-optic transceivers) allow two extenders to make a USB communications link over 
distances in excess of 100

 

meters via fiber optic cables. An internal re-chargeable battery system enables 

remotely powering measurement instruments in locations that are not necessarily close to AC line power. One 
+5 V, four +12 V, and one +20 V supply connections are available. The inclusion of a six-port USB HUB allows 
the extender to support multiple USB devices and interface accessories that may be part of a measurement 
application. Such an application is the ME7868A 2-Port Modular Vector Network Analyzer System.

Figure 1-1.

MN25131A Multifunction Extender

Power Supply

R

EC

H

AR

GEAB

LE

 

B

A

TTER

Y

+5V

+12V

USB 3.0 HUB

Local 

Extender

+20V

Local 

Extender

Remote 

Extender

FIBER

FIBER

FIBER

USB-B

USB-B

USB-A

2.5 Amp max

DC input: 

+15V to +23V

6 Amps

USB-B

2.5 Amp max

4 Amp max total

Battery 

Monitor

USB-A connectors

Summary of Contents for MN25131A Series

Page 1: ...Series Multi Function Extender Anritsu Company 490 Jarvis Drive Morgan Hill CA 95037 2809 USA http www anritsu com Part Number 10410 00783 Revision A Published July 2020 Copyright 2020 Anritsu Compan...

Page 2: ...Front 2 PN 10410 00783 Rev A MN25131A OM...

Page 3: ...nel 2 3 Chapter 3 Performance Considerations 3 1 Power Connection 3 1 3 2 Battery Operation 3 1 3 3 Battery Removal 3 2 3 4 Supply Overload Protection 3 2 SFP Fiber Optic Transceiver Care and Removal...

Page 4: ...Contents 2 PN 10410 00783 Rev A MN25131A OM...

Page 5: ...ing measurement instruments in locations that are not necessarily close to AC line power One 5 V four 12 V and one 20 V supply connections are available The inclusion of a six port USB HUB allows the...

Page 6: ...Introduction 1 2 PN 10410 00783 Rev A MN25131A OM Figure 1 2 The MN25131A modules play a key role in supporting the two 25 meter MS46131As in the ME7868A Modular 2 Port Network Analyzer System...

Page 7: ...BATTERY STATUS Four LEDS show internal battery charge status 25 range for each LED For example if 50 LED is on then battery is charged from 26 to 49 25 LED will turn Orange if charge is 10 25 LED wil...

Page 8: ...when connector is inserted in any of the four LED will turn orange when 3 7A is drawn from the supply LED will extinguish when 4 0 A are drawn 7 USB 3 0 HUB Six USB 3 0 Connections Hub input on rear o...

Page 9: ...ical Fiber Converters on page 3 4 2 FIBER EXTENDER USB Type B to SFP Optical Fiber Converter S and R LEDs indicate Activity on the Fiber Outputs 3 FIBER EXTENDER USB Type B to SFP Optical Fiber Conver...

Page 10: ...2 2 Rear Panel Front and Rear Panel Connections 2 4 PN 10410 00783 Rev A MN25131A OM...

Page 11: ...pin grounded power outlet connected in turn to local AC Mains If a grounded 3 pin outlet is not available use a conversion adapter and ground the green wire or connect the equipment frame to a suitabl...

Page 12: ...y door 3 Pull straight out on the lanyard to remove the battery pack from the unit 3 4 Supply Overload Protection The battery will disconnect the outputs when the load current exceeds 8 amps for 6 sec...

Page 13: ...he front panel of the MN25131A are a USB 3 0 Hub The 6 port Hub appears as two USB 2 0 Hubs and two USB 3 0 hubs on the PC device manager It can control any USB 1 0 2 0 High Speed USB 2 0 Super Speed...

Page 14: ...communications between MN25131A extenders used in long distance ME7868A installations They consist of either USB A or USB B 2 0 connectors which are converted to LC Duplex drivers The USB 2 0 connect...

Page 15: ...Max current at 15 VDC Battery Lithium Ion 11 1V 8 4 Ah 94 Wh capacity Supply Outputs 20 V 5 V 12 V 19 5 20 4 VDC 2 5 Amps Max 4 9 5 1 VDC 2 5 Amps Max 11 7 12 25 VDC 4 0 Amps Max between the four con...

Page 16: ...ew Zealand RCM AS N25 4417 2012 South Korea KCC REM A21 0004 Table 4 4 MIL PRF 28800F Class 2 Environmental Specifications Operating Temperature Range 10 C to 55 C Storage Temperature Range 51 C to 71...

Page 17: ......

Page 18: ...Anritsu utilizes recycled paper and environmentally conscious inks and toner Anritsu Company 490 Jarvis Drive Morgan Hill CA 95037 2809 USA http www anritsu com...

Reviews: