background image

26

Appendix

Initialization

.

Summary of Contents for MG3641A

Page 1: ...Fifth Edition For safety and warning information please read this manual before attempting to use the equipment Additional safety and warning information is provided within the MG3641A MG3642A Synthes...

Page 2: ...ing safety symbols are used inside or on the equipment near operation locations to provide information about safety items and operation precautions Ensure that you clearly understand the meanings of t...

Page 3: ...product s country of origin for re export from your country Before re exporting the product or manuals please contact us to confirm whether they are export controlled items or not When you dispose of...

Page 4: ...EU CE marking 1 Product Model Option MG3641A MG3642A 23 Pattern Generator 2 Applied Directive and Standards When the MG3641A MG3642A 23 Pattern Generator is installed in the MG3641A MG3642A the appli...

Page 5: ...g 1 Product Model Option MG3641A MG3642A 23 Pattern Generator 2 Applied Directive and Standards When the MG3641A MG3642A 23 Pattern Generator is installed in the MG3641A MG3642A the applied directive...

Page 6: ...vi...

Page 7: ...Preparation Before Use 3 2 1 Data and Clock Connectors Labeling 3 2 2 Connection 4 Section 3 Operation Overview 7 Section 4 Detailed Description 9 4 1 Delivery Mode 9 4 2 Data Output Method 13 Sectio...

Page 8: ...II...

Page 9: ...requency Besides when no data pattern is delivered the idle pattern can be delivered Various FSK modulated waves can be output by combining with the FSK encoder which is optionally built in MG3641A MG...

Page 10: ...00000 to 65535 Data bit length setting range 2 to 524288 bit However the last delivery address shall be 65535 Write by 1 byte unit via GPIB Write enabled when the Pattern Generator output is turned OF...

Page 11: ...the Int Mod Cont 1 2 and 3 connectors on the MG3641A MG3642A rear panel Each connector is allocated as follows Int Mod Cont 2 3 1 Data 21 Data 20 Clock MG3641A MG3642A Rear Panel By sticking the attac...

Page 12: ...plemented the Int Mod Cont connections are as follow DATA PATTERN GENERATOR Output ON OFF Data 21 Output Data 20 Output Clock Output Data 21 Input Data 20 Input Clock Input FSK Encoder ON OFF FSK ENCO...

Page 13: ...lision by turning OFF the Pattern Generator output when the FSK modulation is performed by using the external data generator etc Also read the FSK Encoder Operation Manual as well if FSK modulation is...

Page 14: ...6 Section 2 Preparation Before Use...

Page 15: ...It cannot be changed during the data pattern delivery Send Mode Send mode is selected from the one time send Single or the repeating send Continuous by using the Sel F1 key It cannot be changed durin...

Page 16: ...set to ON And the free pattern Defined 1 to 4 can display each name which are consist of maximum eight letters The name is written by the GPIB interface Rtn Configuration 1 TEST 1 2 TEST 2 3 TEST 3 4...

Page 17: ...pattern delivery is finished In the Single mode after the free pattern is delivered once the idle pattern delivery is resumed In the Continuous mode the free pattern delivery is repeated until the sto...

Page 18: ...n is delivered twice the idle pattern delivery is resumed In the Continuous mode the PN9 pseudo random pattern delivery is repeated until the stop operation is performed When the stop operation is per...

Page 19: ...idle pattern delivery is resumed In the Continuous mode the PN15 pseudo random pattern delivery is repeated until the stop operation is performed When the stop operation is performed the idle pattern...

Page 20: ...tern is delivered once the idle pattern delivery is resumed In the Continuous mode the 01 repetition pattern delivery is repeated until the stop operation is performed When the stop operation is perfo...

Page 21: ...tput starting from the specified first delivery address LSB for the specified data bit length taken out from the Data 21 Output Address D7 MSB D6 D5 D4 D3 D2 D1 D0 LSB 65535 65534 65533 00004 00003 00...

Page 22: ...65534 65533 00004 00003 00002 00001 00000 2 Rate D0 D2 D4 D1 D3 D5 Int Mod Cont 2 3 1 Data 21 Data 20 Clock Note When the specified data bit length is an odd number the delivery is made of which bit l...

Page 23: ...ftware specifications comply IEEE488 2 and SCPI Standard Commands for Programmable Instruments GPIB command tree and the command detailed description of Pattern Generator is described in this chapter...

Page 24: ...DEFined4 DEFined4 IDLE IDLE DEFined1 DEFined1 DEFined2 DEFined2 DEFined3 DEFined3 DEFined4 DEFined4 IDLE IDLE DEFined1 DEFined2 DEFined3 DEFined4 IDLE ERASe ERASe ERASe ERASe ERASe Character Character...

Page 25: ...t ON OFF is inquired Response The Pattern Generator status OFF ON Restriction None PATTern SELect Character Function The Pattern Generator delivery data pattern is selected Parameter Character DEF1 DE...

Page 26: ...bps Restriction None PATTern RATE Function The Pattern Generator delivery rate is inquired Response The Pattern Generator delivery rate Restriction None PATTern TYPE Character Function The Pattern Gen...

Page 27: ...Generator free pattern memory Defined 1 to 4 is set Parameter Numeric 00000 to 65535 a decimal number Unit Non term Restriction This cannot be set during the data pattern delivery but can be set in th...

Page 28: ...it length of the Pattern Generator free pattern memory Defined 1 to 4 is inquired Response The delivery bit length of the Pattern Generator free pattern memory Defined 1 to 4 Restriction None PATTern...

Page 29: ...length data Unit Non term Restriction This cannot be written during the data pattern delivery but can be written during idling Write the data after the data erasure PATTern DATA IDLE Numeric Character...

Page 30: ...he data from the free pattern memory before writing data Also when changing written address data erase all the data from the memory by executing the ERASE command and then rewrite data from the first...

Page 31: ...o bit end 0 1 0 0 1 1 0 1 1 0 1 0 0 1 0 0 0 1 0 0 1 1 0 1 1 0 1 0 0 1 0 1 0 0 1 1 0 1 1 0 1 0 0 1 0 PATTern DATA DEFined1 ERASe PATTern DATA DEFined1 00000 10110010 PATTern DATA DEFined1 00001 0010010...

Page 32: ...24 Section 5 Remote Control by GPIB...

Page 33: ...t delivery address DEF3 First delivery address DEF4 First delivery address IDLE First delivery address DEF1 data bit length DEF2 data bit length DEF3 data bit length DEF4 data bit length IDLE data bit...

Page 34: ...26 Appendix Initialization...

Page 35: ...Option 23 Pattern Generator Read this manual before using the equipment Keep this manual with the equipment MG3641A MG3642A Synthesized Signal Generator Operation Manual...

Page 36: ...5 10 27 Minamiazabu Minato ku Tokyo 106 Japan Phone 81 3 3446 1111 Printed in Japan ANRITSU CORPORATION Document No M W1389AW 1 0...

Reviews: