background image

2

Note: One LED output of the ArcPower drivers can be loaded 36 LEDs max.

Always connect outputs side by side, starting from output no.1. Do not omit outputs. If you use less than 12 

outputs in one line, connect the link cables (7),(8) with the first free output next to the last used. 

4

. Connect the ArcPover driver to the mains.

   

Example 1 - correct wiring

The line A is fully used  and the link cable does not have any function, it is connected to the "CABLE TIDY" 

socket. The line B can be loaded with 6 LEDs max. per output and the link cable has to be connected to the 

output no.7.

Example 2 - wrong wiring,connected LED modules will not light

10 ouputs of the line A are used but these outputs have to be connected side by side ,no output can be omit

-

ted  (output no.0).

In the line B, there is not the link cable connected correctly (the output no.7 has to be connected insted of the  

output no. 0).