1. Safety instructions 

 

DANGEROUS VOLTAGE CONSTITUTING A RISK OF ELECTRIC SHOCK IS PRESENT WITHIN THIS UNIT! 

 

Make sure that the available voltage is not higher than stated on the rear panel of the fixture. 
This fixture should be operated only from the type of power source indicated on the marking label. If you are not 
sure of the type of power supplied, consult your authorized distributor or local power company. 
 
Always disconnect the fixture from AC power before cleaning, removing or installing  any part. 
 
 Do not overload wall outlets and extension cords as this can result in fire or electric shock.  
 
Make sure that the power cord is never crimped or damaged by sharp edges. Check the fixture and the power cord 
from time to time. 
 
Do not install the unit near naked flames. 
 
During the operation the housing becomes hot (up to 80°C)

 

 
Refer servicing to qualified service personnel. 
 

This fixture falls under protection class I. Therefore this fixture has to be connected to a mains socket outlet with 
a protective  earthing connection. 

 
Do not connect this fixture  to a dimmer pack. 

 

 
LED light emission. Risk of eye injury. 
Do not look straight at the fixture´s  LEDs during operation. The intense light beam may damage your eyes. 
 

Keep compustible materials at least 20 cm away from the fixture. 

 

If the fixture has been exposed to drastic temperature fluctuation (e.g. after transportation), do not switch it on 
immediately. The arising condensation water might damage your device. Leave the device switched off until it has 
reached room temperature. 
 
 Avoid brute force when installing or operating the fixture. 
 

Summary of Contents for ArcSource Outdoor 24 MC Integral SmartWhite

Page 1: ...Version 1 4 ...

Page 2: ... hat installlation 6 3 3 Connection to the mains 7 ArcSource Outdoor 24 MC Integral SmartWhite DMX protocol 9 5 Control menu map 10 6 Fixture menu 12 6 1 Fixture Address 12 6 2 Fixture information 12 6 3 Personality 13 6 4 Manual mode 14 6 5 Test sequences 14 6 6 Stand alone setting 14 6 7 Special functions 15 7 RDM 17 8 Technical specifications 18 9 Cleaning and maintenance 22 ...

Page 3: ... of power supplied consult your authorized distributor or local power company Always disconnect the fixture from AC power before cleaning removing or installing any part Do not overload wall outlets and extension cords as this can result in fire or electric shock Make sure that the power cord is never crimped or damaged by sharp edges Check the fixture and the power cord from time to time Do not i...

Page 4: ... LEDs with any object when the fixture is under operation The fixture becomes very hot during operation Allow the fixture to cool approximately 30 minutes prior to manipulate with it Operate the fixture only after having familiarized with its functions Do not permit operation by persons not qualified for operating the fixture Most damages are the result of unprofessional operation Do not attempt t...

Page 5: ...n be arranged in any position orientation The LED module can be tilted to desired position by means of the tilt lock Use an Allen key 6 to adjust desired position 0 90 1 LED unit 2 Control unit 3 Antenna only wireless DMX version 4 Tilt adjusting locks 5 U bracket 6 Control board with anti vandal cover 7 Power Data cable 8 LED unit connecting cable ...

Page 6: ...nnector This cap provides declared IP rating of the fixture but when the cap is removed the enclosed antenna must be installed on the fixture to keep declared IP rating of the fixture There is a possibility to install the LED unit and the control unit separately Four holes with diameter of 5 3mm in the control unit are intended for mounting on a flat non flammable surface The length of the connect...

Page 7: ...equiped with with a 5 cored power data cable The 3 cores serve for the power supply and next 2 shielded cores are intended for DMX connection as shown the table Core Connection Core Connection Black Live Red Data Blue Neutral White Data Yellow Green Shielding 0 The power data cable is connected to a junction box as shown on the picture below Connect the junction box acording to the tables below Po...

Page 8: ... data cable for connecting fixtures each other Do not overload the supply line and the connecting leads The max number of connected fixtures in a daisy chain depends on the input voltage 27 fixtures at power supply 230V for power cable 3 x 1 5mm2 13 fixtures at power supply 120V for power cable 3 x 1 5mm2 You have to take into account the the length of power data cable circuit breaker etc at proje...

Page 9: ...00 K White 5000 K White 5600 K White 6300 K Warm white Cool white Rainbow effect with fade time Rainbow effect Reserved step step step step step step Step step proportional step step 4 0 31 32 63 64 95 96 127 128 143 144 159 160 191 192 223 224 255 Strobe Shutter closed Shutter open Strobe effect from slow to fast Shutter open Opening pulses in sequences slow fast Closing pulses in sequences fast ...

Page 10: ...Level 5 Menu Level 6 DMXA 0001 Set DMXA 0001 0512 InFo POn Time Total Reset DMX In Strobe 0 255 Dimmer F 0 255 Temp Current Led Board Highest Led Board High Res Led Board Sw Ver IC 1 IC 2 PErS DMX Pres Mod 1 Mod 2 Mod 3 DMX In Wired Wireless M FTime 0 1 25 5 Display Turn On Off T On Off Contrast 0 100 Backlight 0 100 Temp Uni C F I Ef Pos Warm W 0 255 ...

Page 11: ...nu Level 6 Dimmer F 0 255 Store Defaults Manual Warm W 0 255 Dimmer F 0 255 Test Prg St ALone Auto Run Off Test Prog 1 Prog 3 Pr Play Test Prg Prog 1 Prog 3 Pr Edit Prog 1 Step 01 Prg End 1 40 Warm W 0 255 Prog 3 Step 40 S Tim 0 25 5 sec F Tim 0 25 5 sec Copy S Tim 0 25 5 sec Special rdM Low rdM High LED type RGBW ...

Page 12: ...ress Use this menu to set the DMX address of the fixture Set DMXA Set DMX address Select this submenu to set a DMX start address To set a DMX address 1 Use the UP DOWN buttons to find DMXA 0001 menu 2 Press the ENTER button 3 Use the UP DOWN buttons to select desired start address 4 Press the ENTER button to confirm the choice Note After switching on the ArcSource Outdoor 24 MC Integral will autom...

Page 13: ...this function to read the software version of the fixture processors 6 3 Personality Use this menu to modify the ArcSource Outdoor 24 MC Integral operating behaviour DMX Pres DMX preset Select this menu item to set a desired DMX mode Please refer to the chapter DMX protocol for detail description of each DMX mode DMX In DMX input Use the menu to select mode of receiving DMX signal Wired DMX signal...

Page 14: ...ns to set value press the ENTER button to confirm it 6 5 Test sequences Use this menu to run demo test sequences without an external controller which will show you some possibilities of using the ArcSource Outdoor 24 MC Integral 6 6 Stand alone setting The fixtures on a data link are not connected to the controller but can execute pre set programs which can be different for every fixture Auto Run ...

Page 15: ...saturation C Wheel a virtual colour wheel Strobe a strobe shutter Dimmer a dimmer Dimmer F a fine dimmer F tim a fade time 0 25 5 seconds S tim step time value 0 25 5 seconds COPY this item duplicates the current prog step to the next prog step The item Prg En is increased automatically 6 Use the UP DOWN buttons to set a DMX value of the channel and then press the ENTER button 7 Use the UP DOWN bu...

Page 16: ...e DMX Software Uploader 1 DMX Software Uploader program is available from the Anolis web site at WWW anolis cz 2 Make a new directory e g Anolis_Uploader on your hard disk and download the software into it 3 Unpack the program from the archive II Fixture software updating 1 Determine which of your port is available on your PC and connect it with the DMX input of the fixture if you using the flash ...

Page 17: ... the fixture is still in the updating mode and the display is dark Restart the Software Uploader program and repeat software update from your PC 7 RDM This fixture is ready for RDM operation RDM Remote Device Management is a bi directional communications protocol for use in DMX512 control systems it is the new open standard for DMX512 device configuration and status monitoring The RDM protocol all...

Page 18: ... operation 8 Technical specifications Power supply Electronic auto ranging Input voltage 100 240V AC 50 60 Hz Power consumption 70W 230W power factor 0 81 I 0 3A Allow for a deviation of 10 Optic Effects Light source 6 x 10W SW multi chip LEDs Available optical systems 11 26 36 RGBW colour mixing Built in colour macros Adjustable strobe sequences White colour balance adjusting typical Lumen mainte...

Page 19: ...quency range of 2402 2480 MHz Producer LumenRadio Antenna for wireless DMX version only Max gain 5dBi Strobe Strobe effect with variable speed max 20 flashes per second Pre programmed random strobe pulse effects Dimmer Smooth 16 bit dimming from 0 100 Rigging Via two slots in the fixture base Temperatures Maximum ambient temperature 40 C Maximum housing temperature 80 C Total heat dissipation 240 ...

Page 20: ...ArcSource Outdoor 24 MC Integral SmartWhite 20 Separate control unit Junction box Top hat ...

Page 21: ...2517 CSA O D 6 70mm with connectors 1x Chogori 08BMMA SL8001 male at LED unit and 1 x CGRBDU 08BFFA female at Control unit Note In the case that the control unit is is installed separately max length of connection cable between the control unit and the LED unit should not exceed 20 metres Included items 1 x ArcSource Outdoor 24 MC Integral 1 x Junction box 1 x User manual Optional Accessories Top ...

Page 22: ...ith low pressure water spray Wash the housing with a soft brush or sponge and a mild non abrasive washing detergent Rinse it There are no serviceable parts inside the device Maintenance and service operations are only to be carried out by a qualified person Should you need any spare parts please use genuine parts Specifications are subject to change without notice June 10 2014 ...