Cord plug connection:
Cable
Pin International
Brown
Live
L
Light blue
Neutral
N
Yellow/Green Earth
This device falls under protection class I.Therefore the ArcPower 16x12 has to be
connected to a mains socket outlet with a protective earthing connection.
4.2.Mounting the ArcPower 16x12
The ArcPower 16x12 should be be placed on a non-flammable flat surface in any orientation and fixed by the
four screws.There are four mounting holes of a diameter 5 mm in housing of the driver. Ensure that instalation
place is enough ventilated.
4.3.Conection cables
1.
The adapter cable RJ45/XLR connects the ArcPower 16x1 to the DMX controller.If your DMX controller has
RJ45 socket for DMX output,use RJ45 patch cable for connection with the ArcPower 16x1.
RJ45 plug
DMX 512 XLR plug (male)
View facing pins
Front view of the plug
Pin 1:
Not used
Pin 1:
GND
Pin 2:
Not used
Pin 2:
Data -
Pin 3:
Not used
Pin 3:
Data +
Pin 4:
Not used
Pin 4:
Not used
Pin 5:
+5V
Pin 5:
Not used
Pin 6:
Data +
Pin 7:
Data -
Pin 8:
GND