Summary of Contents for ArcPower 16x12

Page 1: ...Version 1 3...

Page 2: ...operation 6 5 1 Single ArcPower 16x12 installation 6 5 2 Multiple ArcPower 16x12 installation 7 6 ArcPower 16x12 Control menu map 8 7 ArcPower 16x12 DMX protocol version 1 2 10 8 Control board 16 8 1...

Page 3: ...airs and servicing must be carried out by a qualified employee Do not connect this unit to a dimmer pack Use a source of AC power that complies with local building and electrical rules AC power has to...

Page 4: ...AC power source from 100 240 Volts Carefully prepare the end of the the supply cord and fit a suitable plug A 3 prong grounding type plug must be installed following the manufacturer s instructions Th...

Page 5: ...are four mounting holes of a diameter 5 mm in housing of the driver Ensure that instalation place is enough ventilated 4 3 Conection cables 1 The adapter cable RJ45 XLR connects the ArcPower 16x12 to...

Page 6: ...o the fixture 4 Connect the fixture to the mains 5 Set the DMX address on the control board of the fixture see chapter Control board Warning Accidental connection DMX 512 Input Output to non DMX 512 d...

Page 7: ...rcPower 16x12 until all fixtures are connected In this way up to 32 fixtures can be chained together At the last ArcPower 16x12 the data link has to be terminated with a terminator A termination plug...

Page 8: ...0 255 bLu 1 0 255 Stro 0 255 dimr 0 255 tESt St AL Auto OFF tESt EPG 1 EPG 2 PLAY tESt EPG1 EPG2 Edit EPG1 EPG2 St 01 St 60 rEd 1 0 255 dimr 0 255 F tim 0 255 S tim 0 255 COPY SPEC P End 1 64 dM Pr M...

Page 9: ...CHAr EYE LinE i bLi On Off dFSE no YES uPd no YES...

Page 10: ...00 proportional 2 2 11 11 0 255 Green LED 4 Green LED saturation control 0 100 proportional 3 3 12 12 0 255 Blue LED 4 Blue LED saturation control 0 100 proportional ZONE 5 1 1 13 13 0 255 Red LED 5 R...

Page 11: ...35 0 255 Green LED 12 Green LED saturation control 0 100 proportional 3 3 36 36 0 255 Blue LED 12 Blue LED saturation control 0 100 proportional ZONE 13 1 1 37 37 0 255 Red LED 13 Red LED saturation c...

Page 12: ...128 143 144 159 160 255 Shutter Strobe Shutter closed Shutter open Strobe effect from slow to fast Shutter open Opening pulses in sequences slow fast Closing pulses in sequences fast slow Shutter ope...

Page 13: ...0 255 Blue LED 3 Blue LED saturation control 0 100 proportional 4 12 0 255 White LED 3 White LED saturation control 0 100 proportional ZONE 6 1 13 0 255 Red LED 4 Red LED saturation control 0 100 pro...

Page 14: ...ue LED 9 Blue LED saturation control 0 100 proportional 4 36 0 255 White LED 9 White LED saturation control 0 100 proportional ZONE 14 1 37 0 255 Red LED 10 Red LED saturation control 0 100 proportion...

Page 15: ...9 160 255 Shutter Strobe Shutter closed Shutter open Strobe effect from slow to fast Shutter open Opening pulses in sequences slow fast Closing pulses in sequences fast slow Shutter open step step pro...

Page 16: ...ntil the display shows current addres A001 Confirm by pressing ENTER button and A001 will start to flash frequently 3 Use the UP and Down buttons to select the desired address 4 Confirm by pressing EN...

Page 17: ...am No 1 EPG 2 program No 2 PLAY Playing program Select this menu to run a desired program immediately tESt The option starts test program EPG 1 The option starts editable program No 1 EPG 2 The option...

Page 18: ...econds will receive Red 255 DMX It means that red will go to full intensity during 5 seconds Max fade time is reduced from 8 sec to 5 sec Note the value adjusted in the item M F ti will not influence...

Page 19: ...qualified person If you lack qualification do not attempt the update yourself and ask for help your ROBE distributor Note 2 DMX address programs 1 2 and all items in the menu SPEC will be set to thei...

Page 20: ...o update only later versions of processors check the Incremental Update box Avoid interrupting the process Update status is being displayed in the Info Box window When the update is finished the line...

Page 21: ...on LED zones 12 Max load per zone 16 x 1W LED Total max load 12x16 LEDs Maximum total cable length between one zone of the Arcpower 16x12 and connected LED modules 80 metres at max load DMX channels M...

Page 22: ...10 Replacing the fuse 1 Before replacing the fuse unplug mains lead 2 Unscrew the fuse holder on the rear side of the ArcPower 16x12 with a fitting screwdriver from the housing anti clockwise 3 Remove...

Page 23: ...23...