ArcPad 48 Integral (SmartWhite)
16
To set a DMX address.
1.
Use the UP/DOWN buttons to find “
A001
“ menu.
2.
Press the ENTER button.
3.
Use the UP/DOWN buttons to select desired start address.
4.
Press the ENTER button to confirm the choice.
MA.SL. --- Master/slave addressing
. Select this submenu to set the fixture as a master or slave. Option "
d.AbL
"
deactivates master/slave setting.
To set a fixture as a master or slave.
1.
Use the UP/DOWN buttons to find “A001“ menu.
2.
Press the ENTER button.
3.
Use the UP/DOWN buttons to select “
MA.SL.
“ item.
4.
Press the ENTER button.
5.
Use the UP/DOWN buttons to select either master (MASt) or slave (SLA)
6.
Press the ENTER button to confirm the choice.
Note
: After switching on, the ArcPad 48 Integralwill automatically detect whether DMX 512 data is received or not.
If there is no data received at the DMX input, the display will start to flash with actually set address.
6.2 Fixture information
Use this menu to read useful information about the fixture status.
To display desired information.
1. Use the UP/DOWN buttons to find the “ InFo“ menu.
2. Press the ENTER button.
3. Use the UP/DOWN buttons to select the required menu item.
4. Press the ENTER button to confirm the choice.
Po.ti.
---
Power On Time.
Use the menu item to read the number of operation hours for each LEDs operating
mode.
FuLL
---Max light output from the fixture.
totL
- the function shows the total number of the operation hours in the “FuLL” mode since the
ArcPad 48 Integral has been fabricated.
rESEt
- the function shows the number of the operation hours that the ArcPad 48 Integral
has been powered on in the “FuLL” mode since the counter was last reset. In order to reset this
counter to 0 you have to press and hold the UP and DOWN buttons and at the same time press
the ENTER button.
EcO
---Economical mode.
totL
- the function shows the total number of the operation hours in the “EcO” mode since the
ArcPad 48 Integral has been fabricated.
rESEt
- the function shows the number of the operation hours that the ArcPad 48 Integral
has been powered on in the “EcO” mode since the counter was last reset. In order to reset this
counter to 0 you have to press and hold the UP and DOWN buttons and at the same time press
the ENTER button.
DM.In.
---
DMX values
. Select this function to read DMX values of each channel received by the fixture.
tEMP
---
Fixture Temperatures.
Select this menu to read the temperatures of the fixture:
Cur.t.
--- the current temperature of the fixture inside.
Hi.tE.
- the menu item shows the max. temperatures of the fixture inside since
the ArcPad 48 Integral has been fabricated.