English language
Use and Installation
35
7
MAINTENANCE INSTRUCTIONS
Checking the inflation pressure
If the pump has a pressure accumulator, check its
level of inflation, with the pump at a standstill, us-
ing an air gun fitted with a pressure gauge. The ac-
cumulator is inflated by the manufacturer for use
of the pump at its maximum pressure. For adap-
tation of the accumulator pressure to the working
pressure, refer to the table below.
bar
psi
bar
psi
1-3
15-44
1
15
3-12
44-174
1-3
15-44
12-20
174-290
3-5
44-73
20-50
290-725
5-7
73-102
Summary of Contents for BHS 170
Page 2: ...Italiano 3 English 21 Fran ais 39 Deutsch 57 Espa ol 75...
Page 93: ...93...