background image

Table of lubricants 

The pump is delivered complete with  high-performance 

30

 weight, non-detergent oil  suitable for the 

intended ambient conditions (see "Environmental operating limits"). 

Inspecting the pump mounting 

Check that the pump's fixing screws have not become loose. 

If necessary, tighten them with the driving torque stated in the installation design. 

Inspecting the connections and pipes 

- Inspect the connections for leaks.

Leaks can normally be dealt with by tightening the connections properly. 

If leaks from the intake pipeline connections are noticed, the seals must be repaired. 

- Inspect the hoses.

If the pipes show signs of aging, breakage, swelling, rubbing, etc., they must be replaced. 

Inspecting the Inlet Filter 

- Inspect the inlet filter cartridge.

If the cartridge is fouled, wash it thoroughly to remove the dirt.

If the cartridge is torn or cracked, it must be replaced.

Checking the oil level 

- Check  the  oil  with  the  pump  level,  ensuring 

that it has been running for at least 5 minutes in 
normal working conditions.

-

If the oil level is not visible or completely full, 

add or remove oil to restore this level and 
check, still with the pump running, that the oil 
level does not vary so much that it leaks from 
the cap or is no longer visible in the tank.

-

If necessary, top up with oil with A

/R

 

P

remium 

D

iaphragm 

P

ump oil 

P/

64

5

3

2

D

.

-

Check  the  oil  level  regularly,  as  it  may  vary 

significantly with the operating conditions.

To top up with oil proceed as described below. 

1)

Unscrew the cap

 

and pour in oil

.

2) Screw the cap back into place.

�------

A

/R

 

P

ump 

O

il  

P/

N A

R64

5

32D

Summary of Contents for AR 115 bp

Page 1: ...7 9 290 20 5 5 44 0 AR135BP C 33 8 128 0 290 20 6 8 34 2 AR135BP SP 33 8 128 0 290 20 6 8 34 2 AR135BP GR3 4 33 8 128 0 290 20 6 8 44 0 AR135BP GR1 33 8 128 0 290 20 6 8 44 0 AR115BP C1000 24 8 94 0 2...

Page 2: ...35 For Models AR70 AR115 AR135 AR1671 AR31185 For Models AR45 AR60 AR80 Shaft Kit AR43392 1 3 8 Male Spline Shaft Gearbox Kit 3 4 for 5 6 HP Gas Engine Shaft Kit AR43389 1 Male Solid Keyed Shaft For m...

Page 3: ...BP 140 F Max Temperature 1 Inlet 1 Return 1 2 Outlet 3 ucm 3 Remote control unit with working pressure regulating valve opening closing control lever anti drip and glycerin filled pressure gauge with...

Page 4: ...o not draw in liquids at temperatures above 50 C or below 5 C Do not use the pump in drinking water supply systems Do not use the pump on products for human consumption Do not use the pump on pharmace...

Page 5: ...diagram guideline The following is a simplified illustration of the typical installation layout and is purely a guideline Control Unit by pass Control Unit Delivery line filter Tank Agitation Pump In...

Page 6: ...see Technical Data free from restrictions and elbows and with a filter of suitable capacity see Installation For occasional duty such as filling water supply tanks the pump can be operated at a vacuum...

Page 7: ...issing ordamaged contact the dealer or manufacturer to agree the procedures to be followed The packaging material must be disposed of appropriately in accordance with the relevant statutory require me...

Page 8: ...g a vacuum gauge to the pump intake fitting The rated pressure of the outlet hose fittings and clamps must be no less than the maximum rated pressure ofthe pump Replacing the intake and outlet fitting...

Page 9: ...nk oil level as described in the Checking the oil level section Before putting the pump into operation check that the control unit is set for low pressure Starting and stopping the pump To start the p...

Page 10: ...rtridge See Inspecting the filter Pump Checking the oil level See Checking the oil level Connection of pump to power Inspection Every working day source pulley belt coupling Pump Inspect mounting See...

Page 11: ...placed Inspecting the Inlet Filter Inspect the inlet filter cartridge If the cartridge is fouled wash it thoroughly to remove the dirt If the cartridge is torn or cracked it must be replaced Checking...

Page 12: ...he pump of products which are often corrosive and may damage its wetted parts over the long term If thepump is instorageduring the winter in locations with severe weather conditions it is very importa...

Page 13: ...Restriction in intake circuit Intake filter fouled Intakecircuit not airtight Residual air left inside pump Valve plate stuck to its seat Pressure accumulator deflated Pressure accumulator deflated R...

Page 14: ...t worn Oil pressure inside pump too high Restore correct oil level in tank One or more diaphragms ruptured Stop the pump at once Replace the diaphragms 1 Oil on pump body or base Pumpusing too much oi...

Page 15: ...2021 AR North America 24 4 A R NORTH AMERICA A R NORTH AMERICA AR 115 bp AR 135 bp AR 115 bp 1000 rpm Attention Assemble with grease between the plate and the membrane Version SP Version C 2154700 Air...

Page 16: ...nnecting rod 2 37 551040 Bolt TE M10x55 12 Geomet 38 550310 Bushing 1 46 550340 Fitting 1 G M M 1 47 550350 O ring 23 81x2 62 1 48 550242 Ring nut 1 G 1 49 550370 Elbow 1 1 50 540550 Elbow 1 1 2 1 Pos...

Page 17: ...t 1 13 550930 Gear Z 64 1 14 621000 Cover 1 15 180030 Bolt TCEI M8x20 1 T220 T220 16 550950 Bolt TSEI 10x25 3 T180 T180 17 620561 O ring 78x2 5 1 18 550920 Flange 1 19 580230 O ring 69 52x2 62 1 20 62...

Reviews: