(VIII) APPLICABILITY 

 

Electric apparatus

 

Rated Load

 

Maximum Load

 

Power factor cosø

 

 

700W

 

850W

 

1

 

 

550W

 

650W

 

0.7-0.8

 

 

500W

 

600W

 

0.7-0.95

 

 

 

(IX) STORAGE 

When the generator set is not being operated or being stored more than one month, follow these 
instructions: 
1. Drain all the fuel out of the tank, fuel cock, and carburetor. 
2. Shake the tank till all the excess being drain off. 
3. Pour about one tablespoon of motor oil through the spark plug hole, then pull the starter 
several times and install the plug (with ignition off), until you feel that piston is on its compression, 
stop pulling. 
4. Stay the generator set in a dry, well-ventilated place, with the cover place over it. 

   

(X) ACCESSORIES 

1. User’s manual 
2. Sparkplug sleeve 
3. Screwdriver     

 

 

 

 

 

 

 

 

 

 

Summary of Contents for AG-HA-1000D

Page 1: ...MODEL AG HA 1000D GENERATOR OWNER S MANUAL BEFORE OPERATING THIS MACHINE PLEASE READ THESE INSTRUCTIONS CAREFULLY ...

Page 2: ...st fire and explosion should be followed 6 Do not connect to household circuit 7 Do not use in wet condition 8 Keep in flammable away 9 Avoid touching hot parts of the machine 10 When refueling stop engine no smoking do not spill Take appropriate measures to protect your hearing Beware of hot parts II PRE OPERATION PREPARATION 1 To prevent get an electric chock when operating the machine link with...

Page 3: ... oil into one container with mixing ratio 40 1 5 3 After shaking put them into fuel tank III STARTING THE ENGINE Before starting do not connect electric apparatus Picture 5 1 Shake fuel tank before starting engine 2 Turn fuel cock lever to ON Picture 6 3 Turn chock lever to Picture 7 4 Turn engine switch to ON Picture8 ...

Page 4: ...until engaged then put it briskly Picture 9 6 Return chock lever Picture10 IV STOPPING THE ENGINE 1 Before stopping turn off electric apparatus Picture 11 2 Turn engine switch to STOP Picture 12 3 Turn fuel cock lever to OFF Picture 13 ...

Page 5: ...nto AC socket Picture 15 4 SAFETY DEVICES Press the button to reset protector to reduce output load if AC protector turns off Picture 16 RESET Picture 16 OFF VI PERIODIC MAINTENANCE 1 Spark plug per 50h or per one month 1 1 Remove spark plug Picture 17 1 2 Remove carbon deposits Picture 18 ...

Page 6: ... plug gap Standard 0 7 0 8mm Picture 19 2 AIR FILTER TIME per 100h or per one month 2 1 Remove air filter Picture 20 2 2 Wash clearly in solvent Picture 20 2 3 Get Motor oil Picture 20 2 4 Squeeze Motor oil out Picture 20 Warning Never run engine without air filter ...

Page 7: ... Clear in solvent 3 2 2 Wipe off 3 2 3 Insert into fuel tank Picture 22 VII TROUBLE SHOOTING Engine won t start 1 Check fuel 2 Check engine switch 3 Check spark plug 4 If engines still won t start check following 4 1 If fuel cock is clogging 4 2 If air filter is clogging 4 3 Installation and major repair work shall be carried out only by specifically trained personnel 4 4 Or consult dealer or manu...

Page 8: ...ll the fuel out of the tank fuel cock and carburetor 2 Shake the tank till all the excess being drain off 3 Pour about one tablespoon of motor oil through the spark plug hole then pull the starter several times and install the plug with ignition off until you feel that piston is on its compression stop pulling 4 Stay the generator set in a dry well ventilated place with the cover place over it X A...

Page 9: ... are disposed of in landfills or dumps hazardous substances can leak into the groundwater and get into the food chain damaging your health and well being When replacing old appliances with new ones the retailer is legally obligated to take back your old appliance for disposals at least free of charge This appliance is not intended for use by persons including children with reduced physical sensory...