11. MY-SAVER Data transmission description and flow control suggestion 

VER:2020060201 

1.

 

Controller power on and time synchronization 

  After controller is power on, it will send data {REQ100...} each second to inform  

  external device such as computer

PLC

AMS. The external device needs to reply {CMD100,....} 

that to sync the external device time to the controller.

 

 

If the controller does not receive {CMD100,....},{REQ100,...}will be sent again after 10 

seconds. 

2.

 

When controller received barcode information, it will send scanned data and data format 

as {REQ101,...} to external device for control judgement or record saving. External device 

needs to reply {CMD100,....}. 

3.

 

After controller is power on and screwdriver shut off, brake signal format as {DATA100,....} 

will be send. Every shut off will cause column 14 (no. of total tightening on controller) 

to increase by 1. External device needs to reply {CMD100,....}, if not replying CMD100,the 

controller will keep on sending DATA100(only update date time) and column 14 (no. of total 

tightening on controller) value will remain unchanged. 

4.

 

Shut off data will be sent after each shut off. Use the column 14 (no. of tightening on 

controller) to judge if there it is a new shut off data or not. 

5.

 

When controller receive feedback and format as {CMD100,....} from external device, 

controller will resume to automatically send {REQ100,...} and be able to configure 

controller time. 

6.

 

Recommended software control flow as below: 

   P.S: The content of [CMD100] in flow as the below: 

{CMD100,YEAR,MONTH,DAY,HOUR,MINUTE,SECOND,0000,0000,0,1} 

       Str2 0001~9999 YEAR 

Str3 01~12 MONTH 

Str4 01~31 DAY 

Str5 00~23 HOUR 

Str6 00~59 MINUTE 

Str7 00~59 SECOND 

             

Str8 0000-9999 Check Sum (YEAR+MONTH+DAY+HOUR+SECOND = Check Sum) 

       Str9 0000-9999 Key Code (Check Sum + 5438 = Key Code) 

       Str10 (default: 0) 
       Str11 Instruction number (Same as the Instruction number of REQ100) 

 

7. 

 

When the screwdriver is running, it will start transmitting {DATA101,....}  

    until the  screwdriver status (for example: NG,OK...) is generated. 

  

  PS:WIFI and Ethernet will not output {DATA101,...} data. 

 

Summary of Contents for MYTORQ MY-SAVER

Page 1: ...MY SAVER User Manual Model MY SAVER ANLIDAR INDUSTRIAL CO LTD http www anlidar com Y2F214 2E 010 20200312 ...

Page 2: ...method introduction 5 3 1 Hot key function introduction 5 3 2 Enter setting function page 5 4 Control setting 6 5 Program setting 7 6 Screw setting 8 7 Extra function 8 8 CONFIRM mode 9 9 External output control function description 10 10 External input control function description 11 11 Data transmission description and flow control suggestion 12 12 EXPLODED VIEW DRAWING PARTS LIST 14 ...

Page 3: ... SAVER Input Voltage AC 110V 240V Input Frequency 50 60Hz Input Current 6 3A Input Voltage DC 40V Output Current Max 9A Output Power 360W Function Period 1s ON 3s OFF Size 185 x 241 4 x 146 8 mm Weight 3 7Kg DC screwdriver model MY SAVER3 5 7series ...

Page 4: ...nt display for torque value 10 16X4 LCM display setting function 5 ESC button Return Leave Enter setting mode 11 Restart button 6 Up Down Left Right buttons 12 Enter button Select Confirm Job Job project JS Job sequence TP Tightening program TR Tightening repeat Time Display screws Torque Display torque value Status Display status OK NGQ NGC OKALL 4 7 10 11 9 8 12 5 6 2 1 3 ...

Page 5: ...t 8 Wired communication port 3 Barcode scanner USB type A port 9 Protocol output port 4 Micro SD card slot Data Storage 10 Output signal port 5 Socket and switch 11 Input control signal port 6 Voltage Choice Switch 1 DC fuse station Content 10A 250V 2 Grounding station FG 1 2 1 2 3 4 6 5 9 10 11 8 7 ...

Page 6: ... sound 2 Down button Press 3 seconds to return to the last job sequence after beep sound 3 Up button Press up and down button and release to view tool setting 4 Right button Press for 3 seconds to go to the next job sequence 1 Press ESC button for 3 seconds to enter settings after beep sound 2 Input password and press Enter to enter settings 3 Follow below image to enter Control setting Program se...

Page 7: ...se CCE can be set Force Level Number of force segments Force0 disable 1 9 10 100 RPM set to remove the screw speed Job 01 JS 01 TP 00 TR 00 PROGRAM 00 50 Select program 00 DEFAULT N Y Return to default status and remove all memory data N TORQUE UNIT Kgf cm N m kgf m lbf in Set up torque display unit Kgf cm GATE MODE None Once Twice None Function off Once Workpiece in position Short signal Twice Wo...

Page 8: ...r Start Signal Duration of start signal when screwdriver is stopped Motor The start signal disappears when screwdriver is stopped Start signal When the driver is stopped the start switch press lever plate push down external signal is released The start signal disappears Motor 5 Program setting Name Set Up Value Function Description Default setting Screw step 001 250 Step can set the speed target v...

Page 9: ...tting value 2 means when two consecutive errors occurs will lock the screwdriver Setting value 3 means when three consecutive errors occurs will lock the screwdriver and so on If the tightening status is OK once it will be recalculated ON When malfunction signal NS happens it will disable screwdriver immediately User need to press ENTER button to deactivate rotation For I O part But screwdriver ca...

Page 10: ...ide set range No of rotation could be lower than LC or higher than HC Sequence incomplete 1NG F means sequence 1 is not completed properly 2NG F means sequence 2 is not completed properly and so on NA E3 Voltage drop protection When the voltage of the electric screwdriver drops instantly the electric screwdriver will be stopped and the LCM displays this symbol representing that the screwdriver is ...

Page 11: ...rol function description Connector No Symbol Definition Function Description CN 1 START RUN FWD When the screwdriver is on CN1 2 short When it short CN1 CN2 short When it open CN1 CN2 open CN 2 COM CN 3 CN 4 CN 5 REVERSE RUN BWD When the screwdriver reverse CN5 6 short When it short CN5 CN6 short When it open CN5 CN6 open CN 6 COM CN 7 OK OK When a screw is fastened CN7 8 short When it short CN7 C...

Page 12: ...rnal disable signal input DISABLE 1 When CN5 CN6 short CLOSE screwdriver cannot be activated 2 When CN5 CN6 open OPEN screwdriver can be activated CN 6 GND CN 7 External confirm signal input CONFIRM 1 When system requests to press confirm button we can short CN7 CN8 CLOSE instead 2 After CONFIRM is executed the NG signal is also cleared CN 8 GND CN 9 External clear signal input CLEARED 1 To clear ...

Page 13: ...ontroller will keep on sending DATA100 only update date time and column 14 no of total tightening on controller value will remain unchanged 4 Shut off data will be sent after each shut off Use the column 14 no of tightening on controller to judge if there it is a new shut off data or not 5 When controller receive feedback and format as CMD100 from external device controller will resume to automati...

Page 14: ...roller CMD100 Controller send to external device DATA100 After Data101 check column 14 of Data 100 to judge if it is any new data External device response to controller Controller send to external device DATA101 Tool is busy now and keeps sending Data 101 until the tool gets new status Controller MY SAVER Master Controller MY SAVER Master External device PC AMS PLC Slave External device PC AMS PLC...

Page 15: ...te 39 92 Barcode data 11 Tool SN 20 Bytes String 20 Byte 94 113 Screwdriver serial no 12 Device SN 20 Bytes String 20 Byte 115 134 Device serial no 13 Instruction number 1 255 String 3 Byte 136 138 Instruction number 14 Tail String 1 Byte 140 Tail 15 ASCII code LF 16 ASCII code CR REQ101 Total 140 Byte 14 Field Remark 3 DATA100 Data format example Field Parameter Value Data Type String Length Posi...

Page 16: ... Data Type String Length Position Description 1 Header CMD CMD100 String 7 Byte 1 7 Header Command code 2 Year 0001 9999 String 4 Byte 9 12 Year 3 Month 01 12 String 2 Byte 14 15 Month 4 Date 01 31 String 2 Byte 17 18 Date 5 Hour 00 23 String 2 Byte 20 21 Hour 24 hours 6 Minute 00 59 String 2 Byte 23 24 Minute 7 Second 00 59 String 2 Byte 26 27 Second 8 Check Sum 0000 9999 String 4 Byte 29 32 YEAR...

Reviews: