background image

05

06

EMS Mode (Tighten)

Hold the  

  button for 1.5s (Power on) 

to enter EMS mode. 

REJ Mode (Deep SPA)

After powering on, press the  

  button 

once to enter REJ mode. 

R&S Mode (RF & Sonic)

After powering on, press the  

  button 

twice to enter R&S mode. 

USING YOUR 

BEAUTY 

MACHINE

Treatment Modes & Frequency

Skin Allergy Test

Default Light: Red & blue

Default Light: Red & yellow

Default Light: Red

EMS

REJ

R&S

EMS

REJ

R&S

EMS

REJ

R&S

Mode Effects: Micro-current exercises 

muscles, eliminates edema of the skin, 

lifts the jawline, tightens the skin

Mode Effects: Innovative Multipolar 

RF, brand new SPA experience, deeply 

rejuvenates your skin, promotes 

collagen production, anti-aging, and 

wipes out age signs

Mode Effects: Introduces nutrition 

from deep inside to skin surface, 

enhances skin elasticity and 

stimulates collagen production

As shown in the figure, apply a 

proper amount of essence on the 

inner side of your elbow, power 

on the instrument, select a mode 

and a proper intensity level, 

massage the area for 2-3 mins, 

power off the instrument, and air 

dry the area. If no allergic reaction 

within 48 hours, you can use this 

instrument normally.

1.5s

2

Summary of Contents for Beauty Machine AJ-PCA050

Page 1: ...尺寸 170mm 100mm 骑马钉 封面128g铜版纸 内页80g书纸 ...

Page 2: ...www anjou com FIND YOUR BEAUTY Beauty Machine AJ PCA050 User Manual ...

Page 3: ...G 14 CLEANING AND MAINTENANCE 03 04 KNOWING YOUR BEAUTY MACHINE 16 WARRANTY 05 Skin Allergy Test 06 Treatment Modes Frequency 07 Intensity Levels 07 Light Treatment Effects 08 Treatment Skills 10 Daily Use 03 Beauty Machine 04 Accessories 04 Specifications 14 Cleaning 14 Store Disposal ...

Page 4: ...yourbodybeforeuseifany 3 Besurethatyourhandsarecompletelydrywhenoperatingtheinstrument 4 Keep away from sink or bathtub when using DO NOT submerge the instrument under water 5 DO NOT touch the instrument should it fall into water Unplug the instrument immediately with dry hands 6 TurntheinstrumentOFFandthenunplugtheadapterfromthesocket after use or before cleaning and maintenance Product Safety 1 ...

Page 5: ...ndicator REJModeIndicator IntensityLevelIndicator IntensityLevelButton E LightButton Power ModeButton Adapter Holder Model AJ PCA050 Input 100 240V Output 9V 1500mA KNOWING YOUR BEAUTY MACHINE User Manual UserManual Specifications Accessories Beauty Machine TreatmentHead ...

Page 6: ... eliminatesedemaoftheskin lifts the jawline tightens the skin Mode Effects Innovative Multipolar RF brandnewSPAexperience deeply rejuvenates your skin promotes collagenproduction anti aging and wipes out age signs Mode Effects Introduces nutrition from deep inside to skin surface enhances skin elasticity and stimulates collagen production As shown in the figure apply a properamountofessenceonthe i...

Page 7: ...Long termusingofbluelightcanimprovethewater oilbalanceof your skin reduce acne and other skin issues and keep skin in a healthy status Treatment Frequency Usetheinstrumentaccordingtothefollowingfrequency better results can be obtained You can reduce the frequency after two weeks Intensity Levels Light Treatment Effects We suggest you to treat with R S mode first to introduce nutrition before treat...

Page 8: ...enly apply a proper amount of essenceontheskin 1 5s 2 Plug the adapter into a socket and hold the button for 1 5s to power on Press the button to select the desiredmode Pressthe buttonto select the desired intensity level 3 4 5 6 Keep the treatment head cling to skin to ensureproperheating of the treated area Slowlyandconstantly movetheinstrument over the skin Hold the button for 1 5s to power off...

Page 9: ...11 12 Regular Treatments face Regular Treatments face Fromundernosetoeyebrowcorner Fromjawtobaseofear Frommouthcornertotopofear Fromnosetotemple Wingofnose Fromjawtoearside Lowerjaw ...

Page 10: ...S RE RE J J R R S S You CANNOT disassemble theinstrumentbyyourself 1 After treatment power off and unplug the instrument 2 Wipe down residue on the treatment head with a damp cloth or paper towel 3 Place the instrument back in the holder Store the instrument in a dry and shady place DONOTdisposethisproductasgeneraltrash Followyourlocalgovernmentrulesforproper disposal of this product DO NOT rinse ...

Page 11: ...instrumentafter the menstrual period Q Can I proceed to the next treatment after one treatment is over A Yes There is no need for any recovery period or rest time if you have no discomfort nor pain during use Q My skin is sensitive Will it be allergic or painful A Ifso youcandotheallergytestbeforeuse Youmightfeelaslightpainwhen using EMS mode which is normal It is recommended to use the lowest int...

Page 12: ...y to promote the sustainable reuse of material resources Household users shouldcontacteithertheretailerwheretheypurchasedthis product ortheirlocalgovernmentoffice fordetailsofwhere andhowtheycantaketheseitemsforenvironmentallysafe recycling Business users should contact their supplier and checkthetermsandconditionsofthepurchasecontract This product and its electronic accessories should not be mixe...

Page 13: ...nufacturer Shenzhen Danya Technology Co Ltd Address Room705 BuildingE GalaxyWorldPhaseII Minle Community MinZhiStreet LonghuaDistrict Shenzhen China support anjou com www anjou com MADEINCHINA Rev_1 1_EN ...

Reviews: