Anjon AFF3100 Owner'S Manual Download Page 3

3

PUMP AND FOUNTAIN SPECIFICATIONS

MS-3000

MS-5200

MS-6100

MS-8000

Pond Size (surface acres)

Up to ¼

Up to ½

Up to ½

Up to ¾

Range of Fountain Pattern Heights (feet)

4-12

7-16

7-18

10-20

Range of Fountain Pattern Widths (feet)

8-20

10-25

10-28

10-32

Minimum Operating Depth

20"

20"

20"

20"

Max Flow (gph)

3,000

5,200

6,100

8,000

Watts (120v)

192

294

354

520

Amps

1.6

2.45

2.95

4.5

Volts

120

120

120

120

Cord Length (ft.)

100

100

100

100, 200

Dimensions l x w x h

8" x 6" x 6"

9" x 7" x 7"

11" x 6.5" x 6.5"

11" x 8" x 8"

Pump Weight (lbs.)

9

11

13

16

Please read all instructions thoroughly and understand them 

prior to installation or use. If you have any questions or are 

missing pieces, do not contact or return to place of purchase; 

please call 

1-800-553-5605

.

CONTENTS PAGE

Components 4

Nozzle Assembly 

4

Optional Light Assembly 

5

Optional Accessories 

5

Mooring Rope Assembly 

6

Warranty Info 

7

SAFETY INSTRUCTIONS

•  Read and observe all the supplied instructions.

•  Make sure your outlet voltage corresponds to those stated on the rating label of the pump(s).

•  Make sure the pump is securely installed before operating it.

•  The electrical connection should be in a waterproof area and should be at least 6 feet away from the edge of the pond. (see fig. 3)

•  Keep the electrical connections dry! Hang the electrical cord below the electrical outlet to form a "Drip Loop". This will prevent water from 

running down the cord into the electrical outlet.

•  Always unplug the pump when not in use, before putting on or taking off parts, before cleaning the pump and before doing any work  

for the fountain or pond.

•  The pump must not be used when people are in the water. Please disconnect the pump from power supply first.

• Do not operate any appliance with a damaged cord or plug, or in an abnormal state. The supply cord of the pump cannot be replaced. 

• If the cord is damaged, the pump should be discarded. Replacement pumps are readily available.

• Do not cut the plug end off the cord for any reason. Cutting the cord voids the warranty and creates an electrical hazard.

•  For safety reasons, routine cleaning, maintenance or repair work should only be performed with the power cord disconnected from  

the power source.

• Never hang or transport the pump by means of pulling the power cord!

• Close supervision is necessary when the pump is used by or near children.

• To disconnect the pump from the power source, pull the plug by the molded end; never pull the plug by the wire.

•  Never use any accessories which are not recommended by the pump manufacturer. This may result in fire, electric shock, personal injury 

and/or voided warranty.

•  The pump is to be supplied through a Ground Fault Circuit Interrupter (GFCI) with a rated residual operating current not  

exceeding 30mA.

• To protect against the risk of electrical shock, do not immerse the plug in water or other liquid.

• Do not plug the pump in out of water, doing so damages the pump and voids the warranty

• The pump power cable needs to be ran through conduit from your water feature to the GFCI.

• Do not fish around the fountain, this can damage the power cord.

• If operating in winter, be careful of thin ice; the fountain will keep the ice thin and unsafe for walking.

•  Use extreme caution when operating fountain in cold weather and cold water. Do not walk on ice. Thin ice could break, creating the  

risk of hypothermia or drowning.

800-553-5605 • www.anjonmfg.com

Making a Difference

800-553-5605 • www.anjonmfg.com

Making a Difference

Thank You and Congratulations!

Summary of Contents for AFF3100

Page 1: ...OWNER MANUAL MONSOON FLOATING FOUNTAIN MS FA 3 8 800 553 5605 www anjonmfg com...

Page 2: ...variable speed controller not included that permits you to increase or decrease pump flow as needed Vortex impeller passes solids up to 0 25 Engineered for 24 hour continuous use over load sensor pre...

Page 3: ...n the water Please disconnect the pump from power supply first Do not operate any appliance with a damaged cord or plug or in an abnormal state The supply cord of the pump cannot be replaced If the co...

Page 4: ...ting to pump ATTACH MONSOON ADAPTERS TO YOUR MONSOON WATER PUMP 1 Center Monsoon Hub Adapter in Fountain Nozzle Hub 2 Attach Nozzle Quick Release over the Monsoon Hub Adapter and twist to lock 3 Insta...

Page 5: ...m Tube And Adjust Deflector To Set Pattern Spread COLOR CHANGING LIGHTS WITH CONTROLLER Our RGB LED Brass Light kits come in 3 or 9 watts They are available in standard white or remote color changing...

Page 6: ...ure to the float Important Always retrieve the fountain using mooring ropes Never retrieve with the power cord 3 Position the floating fountain in the desired location and set the anchors To keep foun...

Page 7: ...service under this warranty will be accepted if received more than 30 days after the term of the warranty Correction of defects in the manner and for the duration of the warranty described in this wa...

Page 8: ...mfg com E mail sales anjonponds com Making A Difference Register Products Online Review Maintenance Service Advice Design Build Tips in the Knowledge Center Check Out the Full Line of Anjon Products 8...

Reviews: