10
For a standard installation on camera please proceed as below:
- Remove the rear cap (7) and make
sure the rear filter (8) is clean. If not, please refer to maintenance section 8
- Make sure the Optimo Prime PL mount (12) and camera mount are perfectly clean
- Mount the Optimo Prime on the camera mount with electronic pins in the correct orientation. Lock the camera mount
- Remove the front cap (0)
and make
sure the front element (2) is clean. If not, please refer to maintenance section 8
- While using motors, to prevent damaging the lens mechanisms make sure the motors are calibrated properly before operating them
CAUTION:
there are three front
cap types. Type1 for F18-F21-F28-F135, type2 for F24-F32-F40-F50-F60-F75-F100 and type3 for F200.
CAUTION:
for the short focal length up to F28 included, the front engraved ring has an opening. To prevent the cap falling from the lens, make
sure the cap is with its correct orientation so it clamps perfectly on the ring (spring button on the top of the lens towards the largest edge)
3 - General view and installation
2 - Front element
0 - Front cap
3 - Font engraved ring
1 - Front ring
4 - Engraved focus ring
Swappable feet
◄►
meter
(see more in section 7)
5 - Focus gear ring
6 - Focus ring screws (x7)
7 - Rear cap
13 - Serial number ring
12 - PL mount
14 - Iris ring
8 - Rear Filter (Standard or FF)
9 - Rear barrel (Standard or FF)
10 - Retainer
16 - LEMO connector
15 - LEMO connector holder
11 - Connector for metadata
17 - LEMO connector nut