2 - InsTaLLaTIOn
OPTIMO 45-120
15
2 INSTALLATION
2.1 Installation on the camera
remove the front and rear cap
Make sure the rear element is clean and free of dust
Make sure the PL or PV mount on the lens and on the camera are perfectly clean
Mount the lens on the camera
Install the accessories around the lens (matte box, motors,…)
When using a zoom or focus motor mounted on rods, it’s recommended to install
the lens bracket with a standard lens support unit
2.2 Focus
The mechanical flange is setup at 52mm in the air for perfect focus at wide angle.
If needed, flange can be adjusted (see flange adjustment §5.2)
The focus marks are calibrated at ambient temperature for optimized focus at
long focal lenght.
There is a small shift on the marks when using the lens at very high or low
temperatures.
2 INSTALLATION
2.1 installation sur camera
retirez les capuchons avant et arrière.
assurez vous que l’élément arrière est propre et sans poussière.
assurez vous que la monture de l’objectif et de la caméra soient parfaitement
propres.
Montez l’objectif sur la caméra.
Installez les accessoires annexes à l’objectif (matte box, moteurs,…)
Quand vous utilisez une motorisation sur la bague de commande focale ou de
mise au point, il est recommandé de monter l’objectif sur pied avec un support
standard.
2.2 mise au point
Le tirage mécanique est réglé à 52mm pour une mise au point parfaite à la
courte focale.
si besoin, le tirage peut être repris (voir §5.2 réglage du tirage)
Les gravures de la mise au point sont calibrées à température ambiante pour un
réglage optimisé à la longue focale.
Il existe un leger décalage sur les gravures lorsqu’on utilise l’objectif à des
températures très hautes ou très basses.
Summary of Contents for Optimo 45-120
Page 1: ...Optimo 45 120 I user s manual Manuel utilisateur...
Page 2: ...Optimo 45 120...
Page 3: ......
Page 4: ......
Page 5: ...Optimo 45 120 user s manual Manuel utilisateur R f rence 312 836 A Edition May 2012...
Page 8: ...optimo 45 120...
Page 9: ...GENERAL specifications specifications g n rales 9...
Page 12: ...LENS polishing Polissage d une lentille...
Page 13: ...installation installation 13...
Page 14: ......
Page 16: ...Maintenance operation Op ration de maintenance...
Page 17: ...maintenance maintenance 17...
Page 22: ...High precision three dimensional measurement Mesure tridimensionnelle de precision...
Page 23: ...OUTLINE VIEW VUE EXTERIEURE 23...
Page 24: ...24 OPTIMO 45 120 4 OUTLINE VIEW I VUE EXT RIEURE 2 3 1 4 5 6 7 8 9 10 11 Picture 1 Figure 1...
Page 26: ...long distance 131 ft projection room salle de projection longue distance 40m...
Page 27: ...Back focus AND TRACKING ADJUSTMENT r glage du tirage et du tracking 27...
Page 34: ...lens visual inspection contr le visuel d aspect de lentille...
Page 35: ...PANAVISION MOUNT MONTURE PANAVISION 35...
Page 38: ...Ring engraving usinage des gravures...
Page 39: ...Engraved focus ring replacement Remplacement de la bague grav e de mise au point 39...
Page 45: ...outline drawing PLAN D ENCOMBREMENT 45...
Page 46: ...46 OPTIMO 45 120 8 outline drawing I PLAN D ENCOMBREMENT...
Page 47: ...8 outline drawing I PLAN D ENCOMBREMENT OPTIMO 45 120 47...