background image

WARNING: SAFETY AND ELECTRICAL CONNECTIONS 

The pump is supplied with 10 feet of 3 core electrical cable, permanently connected 

and sealed to the motor. The cable cannot be replaced.    Pump should be 

discarded if cord is damaged. 

 

Pump must be connected to an approved ground fault circuit interrupter 

(GFCI) receptacle.    Do not connect to any voltage other than that stated on the 

pump. 

 

Warning: Always unplug or disconnect from the electricity supply before 

putting hands in the water, while equipment is being handled in any way. 

 

Do not use the supply cable to lift the pump as this may cause damage. 

 

  Do not operate or leave the pump in freezing conditions. 

 

Do not allow the pump to run dry. The pump must be fully submerged. 

 

PRE-ASSEMBLY PREPARATIONS   

 

Identify the height of riser and / or other elevation required to feature 

the nozzle at the desired level in your pond.   

 

Assess the parts required from diagram #1, to determine what you will 

need to properly mount the chosen assembly to your pump. 

 

These three popular spray patterns provide you visual and functional 

options that suit most pond sizes and environments. 

 

ASSEMBLY INSTRUCTIONS 

1. 

Attach riser tube pump connector   

      to the base pump output   

 

2. 

Attach Telescoping Riser Tube,   

      and your Fountain Nozzle choice. 

 

 

 

 

 

Fountain Nozzle Head Assembly: 

 

Spray nozzle heads should be   

assembled and connected as   

shown in Diagram # 4. 

 

Please Note: 

Trumpet and Bell Nozzle   

share the same base unit. The feature   

piece is threaded into the base to allow   

adjustment of the water spray diameter.

 

       

INSTALLATION IN POND 

 

Place pump on top of a flat brick or stone approxi

mately 2” from bottom of 

pond to help prevent debris from interfering with the pum

p’s performance.

 

 

 

Make sure the cable is securely routed to the GFCI electrical supply and is 

protected against abrasion and damage.

 

 
CARE AND MAINTENANCE 

Before cleaning, always disconnect the pump from the power supply and 
remove from pond.     

     

 

Do not pump heated liquids. Unit is tested for fresh water use only.

 

 

Pond water must be kept clean using proper filtration components.

 

 

Always operate the pump completely submerged.   

 

Disassemble the unit periodically to clean mineral deposits and build up of 

debris inside the impeller and rotor.   

 

 

 

 

 

 

 

Clean components when visibly soiled or a drop in performance is noted. 

 

Use a cloth or soft brush with warm soapy water when cleaning. 

 

Do not operate this pump below 0

o

C, as FREEZING DAMAGE MAY OCCUR. 