3
Dear Customer,
We thank you for the preference you gave us and we are glad to count you among our customers. We hope the use of this equipment
will satisfy you and your staff.
ALWAYS OBSERVE WARNINGS AND CAUTIONS IN THIS MANUAL
SYMBOL
WARNING
HAZARD LEVEL
CONSEQUENCE
WARNING
POTENTIALLY
HAZARDOUS SITUATION
DEATH OR SERIOUS INJURY
CAUTION
MINOR TO MODERATE INJURY
IMPORTANT
PROPERTY DAMAGE
2. TECHNICAL SPECIFICATION
Max. operating air/fluid pressure: 12 bar (175 PSI)
Air connection:
G1/4"
Noise Level (LAeqT)*:
82.9 dB(A)
Fluid connection:
G3/8"
Weight g (lbs):
395 (0.87)
Max. Temperature range: Atmosphere 5-40°C / Air-Fluid 5-43°C
*Measuring point: 1m backwards from gun, 1.6m height.
WS-200SP
Split Nozzle
NOZZLE
ORIFICE (mm)
AIR CAP SET
MARK
AIR PRESSURE
at Gun Inlet (MPa)
FLUID OUTPUT
(ml/min)
AIR CONSUMPTION
(l/min)
SPRA
Y DIST
ANCE 150 mm
PATTERN WIDTH
(mm)
WS-200SP-0801
0.8
WS-200SP-01
0.25
200
435
210
WS-200SP-1001
1.0
250
230
WS-200SP-1201
1.2
300
240
WS-200SP-1401
1.4
300
240
WS-200SP-1601
1.6
350
255
WS-200SP-1801
1.8
400
265
WS-200FT
Flat Tip Nozzle
NOZZLE
ORIFICE (mm)
AIR CAP SET
MARK
AIR PRESSURE
at Gun Inlet (MPa)
FLUID OUTPUT
(ml/min)
AIR CONSUMPTION
(l/min)
PATTERN WIDTH
(mm)
WS-200FT-0801
0.8
WS-200FT-01
0.25
200
380
240
WS-200FT-1001
1.0
210
WS-200FT-1201
1.2
210
WS-200FT-1401
1.4
300
240
WS-200FT-1601
1.6
WS-200FT-1801
1.8
WS-200FT-0802
0.8
WS-200FT-02
0.30
200
475
215
WS-200FT-1002
1.0
250
250
WS-200FT-1202
1.2
300
255
WS-200FT-1402
1.4
300
255
WS-200FT-1602
1.6
350
270
WS-200FT-1802
1.8
400
285
2.1 TECHNICAL DATA
IMPORTANT
This manual is an integral part of pressure spray gun and must to be read carefully before starting
ANY ACTIVITY involving the use, adjustment and maintenance of the equipment, including its handling.
This manual must be stored in a safe place for any future reference.
Be sure to observe warnings and cautions in this instruction manual.
If not, it can cause paint ejection and serious bodily injury by drawing organic solvent.
This ANEST IWATA pressure spray guns complies to ATEX regulations 2014/34/EU.
Protection level: II 2 G X Suitable for using Zones 1 and 2.
X marking: Any static electricity should be discharged from the spray gun and needs to be diverted to
the ground via a conductive air hose not included.
1. IMPORTANT INFORMATIONS
EN
WS-200SP | WS-200FT Pressure Spray Guns
Summary of Contents for WS-200 FT
Page 51: ...51 Comments ...