Anest Iwata WRA 101-S9 Instruction Manual Download Page 3

HOW TO CONNECT

1.  Fit the gun to fitting stay, aim at spraying direction and fix it.

2.  Connect atomizing air hose to atomizing air inlet (CAP marked side) and operating air hose to operating air inlet (CYL marked side)

tightly.

3.  Connect fluid hose to fluid inlet (FLU marked side) tightly.

4.  Flush the gun fluid passages with a compatible solvent.

5.  Supply paint, test spray and adjust fluid output, air volume and pattern width.

FITTING EXAMPLE

CONNECTING EXAMPLE

DESCRIPTION

REF.

Air cap set

1

Fluid fluid needle set

2

Gun body set

3

Fluid needle packing set

4

Piston

5

Nut

(WRA101 S9N)

6

Piston packing

7

Piston spring

8

Fluid adj. set with micrometer 

(WRA101 S9)

9

Fluid adj. set  

(WRA101 S9N)

9

Stop ring 

(WRA101 S9N)

9-1

Ball 

(WRA101 S9N)

9-2

Fluid adj. spring 

(WRA101 S9N)

9-3

Plug

10

Plug with hexagon hole

11

Cover set

12

Packing

13

Screw

14

3

6

CAUTION

-  Use clean air filtered through air dryer and air filter.

If not, dirty air can cause painting failure.

-

When you use this gun for the first time after purchasing, clean fluid passages spraying thin-

ner to remove rust preventive oil.

If not, remaining preventive oil can cause painting failure such as fish eyes.

- Use two-way or three-way solenoid valve of more than ø 4 inner dia. cross-sectional area and air hose of over

ø 6 inner dia. and less than 10m length.

If not, small dia. of solenoid valve and longer air hose between three-way 

solenoid valve and gun can cause delay in operation.

- Firmly fix hose to spray gun.

If not, disconnection of hose and drop of container can cause bodily injury

.

SPARE PARTS LIST 

Model

Fluid nozzle

Fluid needle

Orifice Ø mm (in)

Mark

set

WRA-101S9-04P

0.4 (0.016)

L50/04

1

WRA-101S9-06P

0.6 (0.024)

L50/06

2

WRA-101S9-10P

1.0 (0.039)

L50/10

3

WRA-101S9N-04P

0.4 (0.016)

L50/04

1

WRA-101S9N-06P

0.6 (0.024)

L50/06

2

WRA-101S9N-10P

1.0 (0.039)

L50/10

3

Marked parts are wearable parts.

-  When ordering parts, specify gun’s model, part name 

with ref. No, and marked No. of air cap set, fluid nozzle 

and fluid needle set.

- When replacing fluid nozzle or/and fluid needle, please 

order nozzle needle set.

WRA-101-S9

WRA-101-S9N

Atomizing  air (TO CAP)

Operating  air (TO CYL)

Fluid line (TO FLU)

Fan air (TO FAN)

In case of circulation usage, connect 

to another FLU marked side.

Air Regulator

Air Filter

Air Filter

Paint pump

Paint flow
meter

Air Compressor

Air Dryer

Air Regulator

Air Regulator

3-way solenoid valve

2-way solenoid valve

2-way solenoid valve

Back pressure valve

Thread for fitting the gun

Thread for fitting the gun

WRA-101 S9N

WRA-101 S9

WRA-101 S9

Summary of Contents for WRA 101-S9

Page 1: ...re 5 40 C Air connection 3 Rc 1 4 Air and fluid 5 43 C Fluid connection 2 Rc 1 4 TECHNICAL SPECIFICATIONS Be sure to observe warnings and cautions in this instruction manual If not it can cause paint ejection and serious bodily injury by drawing organic solvent Be sure to observe following marked items which are especially important WARNING Indicates a potentially hazardous situation which if not ...

Page 2: ...ray gun If done it can cause insufficient performance and failure 2 Enter working areas of other equipment robots reciprocators etc after machines are turned off If not contact with them can cause injury 3 Never spray foods or chemicals through this gun If done it can cause accident by corrosion of fluid passages or adversely affect health by mixed foreign matter 4 If something goes wrong immediat...

Page 3: ...yes Use two way or three way solenoid valve of more than ø 4 inner dia cross sectional area and air hose of over ø 6 inner dia and less than 10m length If not small dia of solenoid valve and longer air hose between three way solenoid valve and gun can cause delay in operation Firmly fix hose to spray gun If not disconnection of hose and drop of container can cause bodily injury SPARE PARTS LIST Mo...

Page 4: ...or protection of the human body Be careful not to damage the tip of the fluid nozzle or not put your hand on it Only an experienced person who is fully conversant with the equipment can do maintenance and inspection CAUTION Never use commercial or other parts instead of ANEST IWATA original spare parts Never immerse the whole gun into liquid such as thinner Never soak air cap set in solvent for ex...