7
2
SAFETY WARNINGS
1. Spark and open flames are strictly prohibited.
Paints can be highly flammable and can cause fire.
Avoid any ignition sources such as smoking, open flames, electrical goods, etc.
2. Never use the following HALGOGENATED HYDROCARBON SOLVENTS
which can cause cracks or dissolution on gun body (aluminum) by chemical reaction.
- UNSUITABLE SOLVENTS: methyl chloride, dichloromethane, 1.2-dichloroethane,
carbon tetrachloride, trichloroethylene, 1.1.1- trichloroethane.
- Be sure that all fluids and solvents are compatible with gun parts.
We are ready to supply a material list used in the product.
3. Securely ground spray gun.
Use air hose with built-in ground wire or use grounded gun stay.
Ground resistance : Less than 1M
Ω
. Check the earth stability periodically.
If not, insufficient grounding can cause fire and explosion due to static electric sparking.
1. Never point gun towards people or animals.
If done, it can cause inflammation of eyes and skin or bodily injury.
2. Never exceed maximum operating pressure and maximum operating temperature.
3. Be sure to release air and fluid pressure before cleaning, disassembling or servicing.
If not, remaining pressure can cause bodily injury due to improper operation or scattering of cleaning
liquid. In order to release pressure, first stop supply of compressed air, fluid and thinner to automatic spray
gun. Next, supply only piston operating air and exhaust fluid by operating fluid needle, which results in automatic supply stop
of all compressed air.
4. Tip of fluid needle set has a sharp point.
Do not touch the tip of fluid needle during maintenance for the protection of the human body.
1. Use in a well-ventilated site by using spray booth.
If not, poor ventilation can cause organic solvent poisoning and catch
fire.
2. Always wear protective gear: safety glasses, mask, gloves.
If not, cleaning liquid, etc., can cause inflammation of eyes and skin.
If you feel something wrong with eyes or skin, immediately see a doctor.
3. Wear earplugs if necessary.
Noise level can exceed 85 dB(A), depending on operating conditions and painting site.
1. Never alter this spray gun.
If done, it can cause insufficient performance and failure.
2. Enter working areas of other equipment (robots, reciprocators, etc.) after machines are turned off.
If not, contact with them can cause injury.
3. Never spray foods or chemicals through this gun.
If done, it can cause accident by corrosion of fluid passages or adversely affect health by mixed foreign matter.
4. If something goes wrong, immediately stop operation and find the cause. Do not use again until you have solved the
problem.
FIRE OR EXPLOSION HAZARD
IMPROPER USE OF EQUIPMENT
PROTECTION OF HUMAN BODY
OTHER PRECAUTIONS
PROBLEMS AND REMEDIES
Problem
Where it
Parts to be
Cause
Remedy
occurred
checked
Retighten Adjust
Clean Replace
Fluid nozzle
fluid needle
* Dirt or damage,
x
x
Fluid nozzle
wear on seat surface
* Wear on needle spring
x
Paint leaks
* Needle does not return due
to paint buildup on
x
x
Fluid needle
Fluid needle packing-
fluid needle.
packing
packing seat
* Wear
x
* Insufficient tightening
x
Fluid adj. knob.
* Insufficient opening
x
Paint does
not flow
Tip of gun
Tip hole of nozzle
* Clogged
x
Paint filter
* Clogged
x
x
TROUBLESHOOTING
Spray Pattern
Problems
Remedies
1. Air enters between fluid nozzle and
1. Remove fluid nozzle to clean seat.
Fluttering
tapered seat of gun body.
If it is damaged, replace nozzle.
2. Air enters at fluid hose joint
2. Fully tighten joint section.
1. Paint buildup on air cap partially
1. Remove obstructions from horn holes.
Crescent
clogs horn holes. Air pressure from
But do not use metal
both horns differs.
objects to clean horn holes.
1. Paint buildup or damage on fluid nozzle cir-
1. Remove obstructions.
Inclined
cumference and air cap center.
Replace if damaged.
2. Fluid nozzle is not properly fitted.
2. Remove fluid nozzle, clean seated section.
1. Paint viscosity too low.
1. Add paint to increase viscosity.
Split
2. Fluid output too high.
2. Tighten fluid adj. knob to reduce fluid output
or reduce air pressure for Fan.
1. Paint viscosity is too high.
1. Add thinner to reduce viscosity.
Heavy
2. Fluid output is too low.
2. Turn fluid adj. knob counter-clockwise to
Center
increase fluid output or increase air pressure
for Fan.
1. Fluid nozzle and fluid needle set are
1. Clean or replace fluid nozzle and fluid
Spit
not seated properly.
needle set.
2. Paint buildup inside air cap set.
2. Clean air cap set.