5
CONNECT GROUNDING
Securely ground the unit, spray gun, workpieces and containers containing paint or solvent.
Be sure to use ground wire set supplied with Multi Spray Unit.
Connect it to ground to have continuous grounding.
Insufficient grounding will cause explosion or fire if exposed to a spark of electricity.
WARNING!
BE CAREFUL ABOUT EXPLOSION
Be sure to use paint pump at less than max. fluid working pressure (section 3.2.).
Use at more than max. fluid operating pressure can cause explosion of pump resulting in great
danger.
Never bend hose with a radius of less than 50mm. Never put heavy things on it (in order not to
damage the hose). If done, hose can explode causing great danger.
Securely connect hose to avoid leak and looseness. If hose is disconnected during operation,
hazardous hose movement and paint ejection at high pressure will cause severe bodily injury.
Never use cracked, damaged, bent, crushed or distorted hose. Leakages from such a hose can
cause great danger during operation.
IMPORTANT
Never alter the equipment
When you replace parts, be sure to always use ANEST IWATA original spare parts. If not done, it
can cause insufficient performance or failure.
Install or keep pump free from rain or splashes. If not done, it can cause pump failure
Install pump on a horizontal surface
Install pump free of paint mist. Attached paint mist etc., can cause pump failure.
Do not run the pump idle.
Do not spray paint or solvents towards the pump.
Use clean air filtered through dryer and filter (finer than 50 microns). If not done, it can cause
pump failure.
* We shall not be responsible for any injury or damage caused by disregard of warnings, cau-
tions or instructions.