30
IMPORTANT: IN CASE OF REPLACEMENT ALWAYS USE GENUINE PARTS
ANEST IWATA. Non original parts may compromise the Unit's operation.
INCONVENIECE
CAUSE
CHECK
SOLUTION
5. The spray gun pattern
size, keeps changing.
Worn out lips seals.
Check the lips seals.
If it is enough, adjust them.
Otherwise, if they are worn out,
replace them.
Damaged or dirty valves or balls.
The unit does not stop.
Disassemble and clean them.
Replace them if they are damaged.
Worn out inner or outer valves
(23 and 17) placed inside the air
motor.
There is a leakage noise.
Replace the valves.
Worn out inner gun nozzle.
Replace it.
Dirty paint filters.
Clean or replace them.
6. The manometer indicates
the presence of pressure
even though the air regula-
tor is closed.
Damaged air regulator.
Replace it.