REPLACEMENT PARTS AND ACCESSORIES

Nozzle (#4)

In time, the nozzle may wear or be damaged and may need to
be replaced.
1. Unscrew the handle (#19).
2. Loosen the needle chucking nut (#18).
3. Gently pull the needle (#17) part way back. It doesn’t need
    to be fully pulled out.
4. Unscrew the head cap (#3).
5. The nozzle should fall out. If it doesn’t, push it gently to the
    side with your thumb.
6. Fit the new nozzle onto the airbrush body.
7. Screw the head cap onto the airbrush body.
 

• Hand tighten cap or “lightly” tighten it with the

 

   provided wrench.

 • 

DO NOT OVERTIGHTEN!

8. Push the needle all the way forward until it seats with the
    new nozzle.
9. Tighten the needle chucking nut.
10. Screw the handle onto the airbrush body.
TIP: Keep a spare nozzle on hand for unforeseen accidents.

Crown Cap (Optional Accessory, Standard on Takumi)

A crown cap replaces the needle cap (#1). It physically protects  

the needle while spraying very fine lines. It also prevents pigment 

build-up and spattering when spraying large backgrounds.

Preset Handle (Optional Accessory, Standard on Takumi)

The preset handle replaces the handle (#19). A threaded adjusting 

screw mounted behind the handle limits the distance the main 

lever can be pulled back. This provides accurate control of paint 

volume and is especially useful when doing repetitive,  

precision work.

13

Nozzle contains Nickel.

Needle (#17)

Iwata needles are made of precision ground and hardened  

stainless-steel that will withstand prolonged usage. They are,  

however, subject to easy physical damage because of the long  

tapered, extremely fine tip. If the needle point becomes severely 

bent, it must be straightened before pulling it back through the 

nozzle. If not, the bent needle might damage the nozzle as it’s  

pulled through.

TIP: Keep a spare needle on hand for unforeseen accidents.

Quick Disconnect (Optional Accessory)

A quick disconnect joint is screwed onto the air hose and a quick 

disconnect adapter is screwed onto each airbrush. When using 

multiple airbrushes, the quick disconnect joint facilitates  

changing airbrushes on the same air hose quickly.

Summary of Contents for Eclipse HP-BCS

Page 1: ...Operating Instruction Manual ECL101 IM NHT...

Page 2: ...to easily atomize heavier sprayable mediums from a controlled fine line to controlled wide spray These capabilities combine to make Eclipse Series airbrushes well suited to almost every airbrush appl...

Page 3: ...om ANEST IWATA RUS LLC Moscow Russia 7 495 938 77 28 www anestiwata ru ANEST IWATA CORPORATION Yokohama Japan 81 0 45 591 1111 www anest iwata co jp ANEST IWATA U K LTD Neots Cambs England 44 0 1480 4...

Page 4: ...y Ideal for users who need a direct line of sight need multiple cup and bottle options who need to spray at odd angles even upside down IWATA ECLIPSE AIRBRUSH SERIES This multi purpose high paint flow...

Page 5: ...th a new funnel shape which makes for easy clean up and more efficient paint flow Sprays heavier mediums while maintaining high detail spray characteristics Gravity feed airbrush features E3 head syst...

Page 6: ...ses 5 Fill the bottle with Medea Airbrush Cleaner or the appropri ate solvent for your paint 6 Attach the bottle to the airbrush by pushing the bottle stem into the bottle joint of the airbrush body 7...

Page 7: ...in lever back much further releasing more paint to cover the bigger area Line thickness can be controlled by adjusting the distance between the airbrush and the surface by manipulating the main lever...

Page 8: ...rsatile spray characteristics of the Eclipse The viscosity of the paint and your desired spray characteristics will also affect your ideal pressure As a general rule larger amounts of paint or thicker...

Page 9: ...of the cup with cleaner 5 Spray cleaner until the spray is clear 6 TAKUMI ONLY Separate cup from adaptor and wipe adaptor and cup threads clean using a paper towel 7 Add the next color to the color cu...

Page 10: ...re smooth main lever action lubricate the needle 17 and the main lever mechanism 12 regularly 1 Unscrew the handle 19 2 Loosen the needle chucking nut 18 3 Remove the needle 4 Coat the needle lightly...

Page 11: ...acked or damaged nozzle Solution Tighten 3 with provided wrench Tighten 2 nger tight See nozzle 4 to reseat the nozzle See nozzle 4 to replace the nozzle See cleaning the needle See cleaning the airbr...

Page 12: ...in cleaner See paint preparation See speci c compressor instructions to lower the air pressure See nozzle 4 to reseat the nozzle See cleaning the airbrush between colors See cleaning the needle See no...

Page 13: ...ment build up and spattering when spraying large backgrounds Preset Handle Optional Accessory Standard on Takumi The preset handle replaces the handle 19 A threaded adjusting screw mounted behind the...

Page 14: ...14...

Page 15: ...I1352 n x x x A I1351 x n n n ITEM DESCRIPTION PRICE CODE ITEM HP BCS HP BS HP CS TAKUMI 16 Spring Guide C I1702 n n n n 17 Needle E5 B I6171 n x x x E3 B I6172 x n n n E3 B I6176 x x x n 18 Needle C...

Page 16: ...purchase This warranty does not cover needles nozzles o rings and internal packings since these parts need to be replaced occasionally due to normal wear Any other parts or materials that are or beco...

Reviews: