TROUBLESHOOTING PROCEDURES
Symptom
•Bubbles in color cup or bottle
•Double Line
•Not Spraying
Problem
•Loose head cap
•Loose nozzle cap
•Improper nozzle to body connection
•Cracked or damaged nozzle
•Dried paint on needle tip (Tip-Dry)
•Dirty airbrush
•Debris on nozzle tip
•Bent needle
•Cracked or damaged nozzle
•Loose needle chucking nut
•Loose head cap
•Improper air pressure
•Paint too thick
•Bottle vent hole is plugged
•Clogged nozzle
•Cracked or damaged nozzle
Solution
•Tighten (#3) with provided wrench
•Tighten (#2) finger tight
•See nozzle (#4) to reseat the nozzle
•See nozzle (#4) to replace the nozzle
•See cleaning the needle
•See cleaning the airbrush between colors
•See cleaning the needle
•See nozzle (#4) and clean nozzle with toothpick
•See needle (#17) to replace needle
•See nozzle (#4) to replace the nozzle
•Finger tighten (#18)
•Tighten (#3) with provided wrench
•See specific compressor instructions
to raise or lower the air pressure
•See paint preperation
•Use pushpin to unclog vent hole
•See nozzle (#4) and clean nozzle with toothpick
•See nozzle (#4) to replace the nozzle
11
Nozzle contains Nickel.