background image

- 2 - 

 

■1.

Safety precaution 

 

 

 

 

WARNING

 

 

Wear protective cover. 

                                                                                                                                                               

During painting be sure to wear protective cover such as glasses, mask or gloves to avoid serious injury 

 

caused by paint or solvent which might enter your eyes or you might in hale. 

 

Be careful about ventilation.   

 

Use it in well-ventilated place. Painting or cleaning in a narrow place with insufficient ventilation can cause   
organic solvent intoxication by sprayed mist of paint or solvent.     

 

If you feel any abnormality during operation, consult with a medical doctor immediately. 

 

 

Be careful about bodily injury. 

                                                                                                                                                               

Never point gun toward person or animal. Never pull trigger of gun when human body or fingers come   

near tip of nozzle tip. 

 

Contact is forbidden. 

 

When paint leaks, never try to stop it by hand. In that case, stop pump immediately and reduce paint pressure   
down to [0 MPa]. 
High pressure paint emitted through small hole can pierce an iron plate and can cause severe injury since   
paint can enter human body directly through eye, mouth or skin. It is very dangerous. If you feel any abnormality 
or receive any injury, consult with a medical doctor immediately. 

 

 

Keep away from origins of explosions or fires. 

                                                                                                                                                               

Never use near sparks or open fire. Especially the following will cause fire. 

Open flames such as cigarettes, pipes. 

Electric goods such as stoves, lamps or heaters. 

 

Connect grounding. 

 

Securely ground pump, airless spray gun, work piece and containers containing paint or solvent. Be sure to use   
ANEST IWATA’s designated nylon (fluid) hose (for airless use such as NHS nylon hose) to have continuous   
grounding between pump and airless gun. Use conductive container containing paint or solvent. 
Insufficient grounding will cause explosion or fire by spark of electric it. 

 

Be careful about explosion. 

 

Be sure to use airless spray gun at less than max. operating pressure. Usage at more than max. operating pressure   
Can cause explosion of gun resulting in great danger. 

Never bend nylon (fluid) hose with a radius of less than 50mm. 

  Never put heavy things on it in order not to damage the hose. If done, hose can explode causing great danger.   

 

Securely connect nylon (fluid) hose. 
If hose is disconnected during operation, hazardous hose movement and paint ejection will cause severe bodily injury.

 

 

 

WARNING

 

Be careful about explosion. 

 

Never use cracked, damaged, bent or crushed nylon (fluid) hose. 

  High pressure paint emitted at small hole can pierce an iron plate and cause great danger. 

Be sure to stop pump, reduce fluid pressure down to [0MPa] and securely apply safety lock of gun before you fit remove nozzle tip. 
Emission of paint or solvent during operation can cause great danger. 

 

 

 

Never alter the equipment. 

When you replace parts, be sure to use our genuine parts. If not done, it can cause insufficient performance or failure. 

Never use the following halogenated hydrocarbon solvents: 

  Methyl  chloride,  dichloromethane,  1,2  –  dichloromethane,  carbon  tetrachloride,  trichloroethylene,  1.1.1  –  trichloroethane  which  can 

cause cracks or dissolution on gun body by chemical reactions. (Be sure that all fluids and solvents are compatible with gun parts. 

  We are ready to supply a material list used in the gun on request.) 

 

Summary of Contents for ALG-7

Page 1: ...G 1 4 G 3 8 bar PSI m m...

Page 2: ...mm...

Page 3: ...ALG 73 No...

Page 4: ...bar PSI No cm cm MPa cm ml sec cm...

Page 5: ...7 72 73 7 72 73 G1 4 7 72 G3 8 73 7 73 72 72 72 7 72 73...

Page 6: ...This warranty is valid only in Japan 9 00 12 00 13 00 17 00 http www anest iwata co jp No 1035 6 No 03511173 223 8501 3176 http www anest iwata co jp...

Page 7: ...ed nozzle tip NT 3005 Fluid pressure 10 MPa 100 bar 1440 PSI Measuring point 1m backwards from gun 1 6 m height Max Temperature Atmosphere Air Fluid Main specifications Model Use Hose connection Filte...

Page 8: ...ed nylon fluid hose for airless use such as NHS nylon hose to have continuous grounding between pump and airless gun Use conductive container containing paint or solvent Insufficient grounding will ca...

Page 9: ...ct nylon fluid hose Securely connect nylon fluid hose When paint leaks never try to stop it by hand In that case stop pump immediately and reduce paint pressure down to 0 MPa Be sure to use our design...

Page 10: ...eaning and maintenance Fully clean after job is finished in order to get longer lifetime and good performance at next job During painting be sure to wear protective cover such as glasses mask or glove...

Page 11: ...aint 2507 4009 Commonly used Ship bottom paint Tar epoxy paint 3011 4013 Last two digits are large due to high viscosity Zinc rich paint organic 2507 4009 Commonly used Zinc rich paint non organic 301...

Page 12: ...Replace with new tip or proper sized tip Paint does not stop smoothly Pump pressure is too high Reduce paint pressure down to 25 MPa 250bar 3 626PSI Paint leaks from the gun tip Paint sticks to needle...

Page 13: ...13 1 universal joint G 1 4 1 for 7 72 7 needle set 1 13 2 universal joint G 3 8 1 for 73 7 1 needle bar set 1 14 trigger stud 1 7 2 conical spring holder 1 15 hex cap nut 2 7 3 conical spring washer...

Page 14: ...8 Manual No 1035 06 Code No 03511173 3176 Shinyoshida cho Kohoku Ku Yokohama 223 8501 Japan...

Reviews: