ANEMOI AIRPRO 250 M Installation Manual Download Page 33

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

www.anemoifans.com 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Summary of Contents for AIRPRO 250 M

Page 1: ...AIRPRO M Installation Manual Issued January 2020 ANIM08AI Rev A...

Page 2: ...O M 2 UPDATES DATE UPDATE DESCRIPTION 26 02 2020 A First Edition Technical documents are regularly updated Anemoi reserves the right to modify the contents of this manual in full or in part without wa...

Page 3: ...5 Ceiling Mount Bracket 15 5 6 Extension Rod Assembly 16 5 7 Motor Assembly 17 5 8 Safety Cable Installation 18 5 9 Wiring Location 19 5 10 Extension Tube Shield Installation 20 5 11 Guy Wires Fixatio...

Page 4: ...rious injury or death Do NOT use wires with worn or damaged insulation Doing so may result in serious or fatal electrical shock fire or other accidents Ensure that the wires are held securely and prot...

Page 5: ...d in the brushless motor and the Modbus drive is located in the ceiling mount The main characteristics are EC brushless motor without gearbox 133mm ultra thin motor Extremely silent fans 7 aluminium b...

Page 6: ...100rpm 70rpm 56rpm Protection degree IP55 IP55 IP55 IP55 Sound level 40dBA 40dBA 40dBA 40dBA Total weight 25kg 28kg 31kg 34kg Operation temperature 10 C 50 C without derating Motor type Brushless EC...

Page 7: ...The height of the fan can also be varied by changing the length of the extension rod The next figure shows the fan dimensions with an extension drop of 643 mm Model D A B H1 H2 H3 H4 250 M 2 5 m 350 m...

Page 8: ...500 29 Blades 1900 250 250 12 4 2 Packing List The following tables include the different pieces sent inside the boxes Please check the status and quantity of the fan equipment and the supporting part...

Page 9: ...50 bolts 4 M10 Flat washer 8 M10 Spring washer 4 M10 Nut 4 Mounting Bracket M10 35 bolts 4 M10 Flat washer 8 M10 Spring washer 4 M10 Nut 4 Extension rod M10 70 bolts 3 M10 Spring washer 3 M10 Nut 3 Ex...

Page 10: ...rope clamp B Safety cable C I beam clamp D I beam shim E Mounting base F Mounting bracket G Fixed angle mount bracket shim H Extension tube I Extension tube shield J Extension tube clamp K Guy wire b...

Page 11: ...revent anyone from going under the fan It is recommended to fence at least four meters around the lifting equipment Follow any national or local regulation regarding installations in height SAFETY Ens...

Page 12: ...necessary to avoid the strobe effect Ensure that the fan is installed at a height greater than four meters The next figures show all clearances If the fan is installed in an inclined roof ensure that...

Page 13: ...ppers 1 5 3 I Beam Conditions In case of I Beam installation make sure the minimums requirements are met Please consult with structural engineer to make sure your building is approved for fan installa...

Page 14: ...orque generated by the fan Having been familiar with the functions of the safety cable For the fan installation the fan blades should be at least 3 05 meters above the ground Please refer to section 5...

Page 15: ...d roofs 1 Secure the Mounting Base to I beam or directly to concrete ceiling Recommended tightening torque 24Nm Use Mounting Base Bolt Kit 4 x M10 50 2 Attach the Mounting Bracket to the Mounting Base...

Page 16: ...provided it must be tightened to avoid balancing the extension With the help of one level we will ensure that the extension bar is completely vertical 4 Insert the extension tube into the Mounting Br...

Page 17: ...Recommended tightening torque 12 Nm Use Motor Tube Bolt Kit 3 x M8 55 CAUTION Make sure that the Earth Wire and Guy Wire stay outside the Extension Tube Failure to do so may result in equipment damag...

Page 18: ...afety cable must be tightened as picture shown make sure the U shaped inside the wire rope clamp is tighten to the short side Use 4 x Wire Rope Clamp and 1 x Safety Cable If the fan is anchored to a c...

Page 19: ...p a circle 8 2 Connecting the Ground Line and Neutral wires with motor and indoor wiring Please refer to Wiring Diagram at section 6 Electrical installation L Line wire N Neutral wire E Ground wire SA...

Page 20: ...e extension tube shied with bolts after fasten all the safety cables and wires Recommended tightening torque 5Nm Be careful by installing so do not damage the wiring Use Extension Tube Shield Bolt Kit...

Page 21: ...d 10 2 Looking up from the bottom of ceiling fan the angle between each cables and I beams is recommended to be 45 degrees 10 3 The angle of the cables should be and 45 degrees angle from horizontal s...

Page 22: ...ure shown Adjust the turn buckle to make sure the ceiling fan reach the balance Repeat this step 4 times to complete the Guy Wires Fixation Recommended Tightening Torque 5Nm Use 8 x Wire Rope Clamp an...

Page 23: ...any damage on the blades paint The fan blades must be installed in a specific sense with the concave side in the bottom 15 Insert the blade into the motor bracket and tighten it Recommended tightenin...

Page 24: ...ply to prevent any accident Check that power supply is disconnected before starting the installation All cabling must comply with national and local regulations on cable cross sections and ambient tem...

Page 25: ...isk of serious or fatal electrical shock fire or other accidents Do NOT connect the motor to the input line directly Failure to do so may result in equipment damage 6 1 Remote Control Fan Installation...

Page 26: ...rocess in one minute You need to set up the receiver for the fan to work properly Please follow the following steps 1 Press these two buttons at same time at least 2 seconds to enter pairing process 2...

Page 27: ...ielded cable type Modbus cable RS485 2x2x0 50 mm POSCY The control board fan is located at the top of the mount bracket the connections and distances are shown below PORT DEFINED Modbus Control Line B...

Page 28: ...be installed for each fan it is recommended an 20mA Circuit Breaker In other to avoid motor damages WARNING Never mix electrical and control wiring Doing so may lead to interference A 20mA circuit bre...

Page 29: ...sing control connections The connection must be made in series The next figure shows the correct connections WARNING Never mix electrical and control wiring Doing so may lead to interference The earth...

Page 30: ...e as shown below 3 Please keep always a distance of at least 20cm between the power and the data cable If both cables must cross at some point please ensure that they do so at a 90 angle to prevent in...

Page 31: ...or vibrations Check that the blades have not received any impact Yearly Check that there no alarms or faults in the variable speed drive located in the control box Ensure that the extension rod screws...

Page 32: ...quick solutions Observation Probable cause Inspection method Abnormal sound from the fan Blades may not be tightened to the specifies torque Check the tightening torque Check the blades position The...

Page 33: ...www anemoifans com...

Reviews: