INSTALLATION CLEARANCES
11
6.
Installation Clearances
Item
Distance from combustibles
• Maintain the following clearances
from both combustible and
non-combustible materials.
• There must be a clearance of 600mm or
more in front of the exhaust terminal.
• This restriction will not be applied to an
area where an effective shield makes a
clearance of 600mm or more in front of
the exhaust outlet.
Check
Illustration
Caution
Clearances to Opening
into Any Building
Combustibles
300 mm
or more
Combustibles
Combustibles
Combustibles
Combustibles
150 mm
or more
150 mm or more
600 mm
or more
10 mm
or more
There must be no
building opening
within this area.
150 mm
or more
150 mm
or more
150 mm
or more
300 mm
or more
Before installing, check for the following:
Install in accordance with relevant building and mechanical codes, as well as any local, state or
national regulations.