21
Shutdown Instructions
1. Stop any water demand.
2. Turn off electric power.
3. Turn the gas control manual valve clockwise to the off position.
Should overheating occur, or the gas supply fail to shut off, turn off the gas control manual valve to
the appliance.
Handling after trial operation
• In Freezing areas: If the unit will not be used immediately, close off all gas and water shutoff
valves, drain all of the water out of the unit and the plumbing system to prevent the unit
and system from freezing, and bleed the gas out of the gas line.
Freezing is not covered by the warranty.
Caution
(1) Open a hot water fixture and confirm that the Burner On indicator comes on, and that hot water
is being produced. (If necessary, repeat until the air in the gas piping is bled out).
* White smoke may be noticed from the exhaust pipe during cold weather. However, this is not a
malfunction of the unit.
* If an “11” error code appears on the remote controller, turn the unit off and then back on again,
and then open a hot water fixture again.
(2) Change the temperature setting on the remote controller and check that the water temperature changes.
• If the water heater does not operate normally, refer to "Troubleshooting"
in the Operation Manual.
* After the trial operation, clean the filter in the cold water inlet.
12.
Commissioning
The installer should test operate the unit, explain to
the customer how to use the unit, and give the owner
this manual before leaving the installation
• Preparation ... (1) Ensure all lines are purged / flushed of debris prior to connection to appliance.
(2) Open the shut off valve on the water supply, check that water passes through the
valve and close the valve.
(3) Open the gas supply valve, turn on the power supply, and turn on the Operation
switch on the remote controller (the Operation lamp turns on) .
NOTE:
The appliance has been factory set and no adjustment is necessary.
<If installed with a quick connect multi-system>
• Turn the system power on with the remote controller.
• Slowly open a hot water fixture and check that the units ignite sequentially. Check to see that the
hot water temperature is the same as the temperature displayed on the remote controller. (*1)
* If inlet water temperature is high, and both units do not ignite at the same time, switch which
unit will ignite first by pressing the Max. or Min. Manifold Pressure Set Button on the circuit
board and then confirm each unit can ignite. (*2)
* If an 11 or F11 error code flashes on the remote controller, hit the Power Button on the remote
controller off and on 2-3 times.
* If (*1) and (*2) cannot be done, the Quick Connect Cord may not be properly connected.
Check that the cord is properly connected.
Unit A Ignites
Unit B Doesn't Ignite
Press Max. or Min. Manifold
Pressure Set Button on Unit B
Unit A Doesn't Ignite
Unit B Ignites