Measuring Gas Pressure
In order to check the gas supply pressure to the unit, a
pressure measurement port is provided on the gas inlet.
Remove the hex head screw from the pressure mea-
surement port, and connect a manometer using a silicon
tube.
Follow the instructions from the gas supplier.
9.
Gas Piping
The appliance and its individual shutoff valve must be disconnected from the gas supply piping system
during any pressure testing of that system at test pressures in excess of 35 mbar.
The Appliance must be isolated from the gas supply piping system by closing its individual manual shutoff
valve during any pressure testing of the gas supply piping system at test pressures equal to or less than
35 mbar.
The appliance and its gas connections must be leak tested before placing the appliance in operation.
The inlet gas pressure must be within the range specified. This is for the purposes of input adjustment.