Page 18
CONTAINER FULL (AMBER).
POSITION VARIES WITH
MACHINE.
DEFROST LIGHT :-
STANDARD --- WHITE
CONVEX CONSOLE ---
GREEN
1
2
3
4 5
6
7
8
PAC15AX/ET15AX
(For convex console see p.25)
10
C
34
C
1
2
3
4
5
6
7
8
THERMOSTAT KNOB
MAINS LIGHT
(RED)
MODE
SWITCH
FAN ONLY
POSITION
COOLING
POSITION
FAN SPEED
SWITCH
FAN SPEED
HIGH
FAN SPEED LOW
COOLING LIGHT
(GREEN)
ATTENTION LIGHT
(AMBER)
HIGH
PRESSURE
RE-SET
LOW PRESSURE
RE-SET
DEFROST
LIGHT (WHITE)
OFF
POSITION
PAC22AX
FIG.3 CONSOLE LABEL/ MARKING OPTIONS WITH
DIAL THERMOSTAT
7) OPERATING INSTRUCTIONS.
The Control Panel on the room unit is
illustrated below, see Fig 3.
AIR CONDITIONER (NOT PAC22 MK3)
a) Revolve thermostat knob fully
CLOCKWISE to the number "8" position.
b) Plug in the room unit mains cable, and
switch on electricity, red mains light will
illuminate.
c) Select "Fan Only" with the mode switch.
The fan will start.
d) Select "Fan Speed", with the fan speed
switch, high or low depending on air
velocity required.
e) Select "Cooling" with the mode switch,
and revolve the thermostat knob fully
ANTICLOCKW ISE to the number "1"
position. If fitted the external heat exchanger
fan and the water pump in the room unit will
start. After a delay of 5 to 10 minutes the
green "Cooling" light will illuminate and the
machine will proceed to cool the air.
f) Monitor the room temperature and when
it has reduced to the desired level, very
slowly revolve the thermostat knob back,
clockwise, until the green "Cooling" light
goes out. The room unit will now control the
room temperature cooling automatically at
this setting.