TECHNICAL DATA
SECTION 2
5
A.
Height of Heater
mm
1623
1623
1623
1851
In
64
64
64
73
B.
Diameter mm
720
720
720
720
In
28
28
28
28
C.
Gas Connection
mm
355
355
355
355
In
14
14
14
14
D.
Cold Inlet
mm
530
530
530
530
In
21
21
21
21
E.
Optional Front Outlet
mm
1307
1307
1535
1535
In
51
51
60
60
F.
Height to Centre of Flue
mm
2060
2060
1980
2217
In
81
81
78
87
G.
Height to Flue Spigot
mm
1780
1780
1780
2020
In
70
70
70
80
H.
Min. Flue Horizontal
mm
1100
1100
1260
1260
In
43
43
50
50
Max. Flue Horizontal
mm
7000
7000
7000
7000
In
276
276
276
276
I.
Min. Flue Vertical
mm
1310
1310
1610
1610
In
51
51
63
63
Max. Flue Vertical
mm
7000
7000
7000
7000
In
276
276
276
276
J.
Electrical Connection
mm
1250
1250
1250
1480
In
49
49
49
58
K.
Flue Diameter
mm
100/150
100/150
130/200
130/200
L.
Flue Adaptor
mm
95
95
In
4
4
ANDREWS MODEL NO.
CSC39
CSC59
CSC78
CSC93
DIMENSIONS
AND
CLEARANCES
Not supplied with
these models
Horizontal or
Vertical Flue
1168mm
Minimum
Service
clearance
with
standard
Anodes.
500mm Recommended
for panel access and
switching. Absolute
min 300mm.
500mm Recommended for
panel access and switching.
Absolute min 300mm.
615mm
Minimum
Service
clearance
with Correx
Anodes.
Adaptor
Cold Water
Inlet 1
“
B.S.P.
Drain or Return
3/4” B.S.P.
Ideal Service clearance Dimensions
1125
Horizontal
Flue can
be rotated
360º
Tee & T/P Valve
supplied
Vent from here
if used for Top
Hot Water outlet
‘X’
H
H
K
I
I
Can be
used for
Hot Water
outlet or
can be
capped
Alternative
Hot Water
outlet
If side connection is
used for Hot Water
outlet Air vent must
be fitted at ‘X’
UNVENTED SYSTEM
VENTED SYSTEM
CSC78 and CSC93 Alternative Flue Systems
CSC39 and CSC59 Alternative Flue Systems
275.0
90.0
725.0 Min.
475.0
300mm
Minimum
N.B. Access of 500mm must be provided
one side for 6 months fan lubrication
Summary of Contents for CSC39
Page 3: ......
Page 5: ......
Page 16: ...INSTALLATION SECTION 3 11 Fig 4 Wiring Diagram for LPG Appliance ...