                                                  Andrew Corporation – Base Station Systems Group                                                Page 6 

Proprietary – Use pursuant to Company Instruction 

Installation and Operation Set-Up 

 
Each OneBase™Cell Extender subrack is specifically designed for a specific cellular 
system by using the correct combination of components and the correct electrical wiring 
and RF cabling of these components. The components of the OneBase™Cell Extender 
subrack are electrically connected with a combination of blind mate rear connections and 
front panel connections to optimize flexibility and ease of maintenance. 
 
The MCPA Modules are vertically arranged and blind-mated to their RF and DC/control 
interfaces in the rear of the subrack.  The RF Interface Module (RFIM) is also vertically 
arranged and is located to the right side of the MCPA modules. The Filter Modules are 
situated at the top portion of the subrack mounted either vertically or horizontally. The 
filters interface to the SCM through blind-mate “N” connectors.   
 
 

FCC Statements:    FCC ID: S8L-OBEMCPA 

 
This device complies with Part 2, 15, 22, and 24 of the FCC Rules. Operation is subject 
to the following two conditions: (1) this device may not cause harmful interference and 
(2) this device must accept any interference received, including interference that may 
cause undesired operation. 
 

Warning  

Changes of modifications not expressly approved by the manufacturer could void the 
user’s authority to operate the equipment. 
 
RF exposure compliance is addressed at the time of licensing, as required by the 
responsible FCC Bureau(s), including antenna co-location requirements of 1.1307(b)(3). 
 
 

Industry Canada Statements:   IC:2237F-OBEMCPA 

 

1. Quality Norms : 

The testing of the equipment is carried out as the norms laid in IC 

standards. 

 

 

2. Labeling : OneBase™ Cell Extender subrack when sold in Canada will have: 

 

(a) The certification number, prefixed by the term "IC: ", i.e. IC:2237F-OBEMCPA  
(b) The manufacturer's name, trade name or brand name, i.e. Andrew Corporation 
(c)  A model name or number. Model Name =  OneBase™ Cell Extender 
(d)  This device complies with RSS-131, RSS-102 of the IC Rules. 

 
3. External Control 

 

The OneBase™ Cell Extender subrack does not have any external controls accessible to 
the user for any adjustments, to operate in violation of the limits prescribed in this 
Standard. Furthermore, information on internal adjustments, reconfiguration or 

Summary of Contents for OneBase Cell Extender

Page 1: ...Base Station Systems Group Proprietary Use pursuant to Company Instruction OneBase Cell Extender Model OBE DB X Operation Instruction December 20 2006 Version 1 0 Reference Numbers FCC ID S8L OBEMCPA...

Page 2: ...nalog air interfaces System Specifications System specifications for the OneBase Cell Extender Subrack are Parameter Specification Frequency Bands 850 MHz Band Tx 869 894 MHz 1900 MHz Band Tx 1930 199...

Page 3: ...Module Filter Module 850 MHz or 1900 MHz PDP Power Distribution Panel Inputs and Outputs Inputs and Outputs The amplifier is powered from a DC supply voltage which can range from 20VDC to 30VDC with a...

Page 4: ...Andrew Corporation Base Station Systems Group Page 3 Proprietary Use pursuant to Company Instruction System Pictures Front View Rear View...

Page 5: ...continue operating Critical Conditions which result in sector shutdown preventing any further cellular call traffic MCPA LEDs MCPA LED Status Alarm Severity Possible Failure Modes Green ON Yellow ON...

Page 6: ...nal temperature above approximately 80 C Green ON Red FLASHING Major 1 Major failure or one or more MCPAs as follows a RF disabled via MCPA panel switch or RFIM command b RF Overdrive gain reduced c D...

Page 7: ...Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause unde...

Page 8: ...he time of licensing 5 Multi carrier operation Rated output power of the equipment is for multi carrier operation which is 426 Watts maximum total composite For multiple carriers the total output powe...