Operation Guide 

Template version:1

 

7/15 

c. 

You  can  turn  off  the  monitor  by  pressing  “START”  button  when  the  minute  is 

blinking, then the time and date is confirmed. 

d.  The monitor will turn off automatically after 1 minute of no operation with the time 

and date unchanged. 

e.  Once you change the batteries, you should readjust the time and date. 

 

3.  CONNECTING THE CUFF TO THE MONITOR 

 

Insert the cuff tubing connector into the socket in the left side of the monitor.    Make 

certain that the connector is completely inserted to avoid air leakage during blood pressure 

measurements.

 

 

 

 

 

 

Avoid compression or restriction of the connection tubing during measurement

which may cause inflation error, or harmful injury due to continuous cuff pressure. 

 

4. 

  APPLYING THE CUFF

 

 

a.  Pulling  the  cuff  end    through  the  medal  loop  (the  cuff  is 

packaged  like  this  already),  turn  it  outward  (away  from  your 

body) and tighten it and close the Velcro fastener. 

b.  Place the cuff around a bare arm 1-2cm above the elbow joint.   

c.  While seated, place palm upside in front of you on a flat surface 

such as a desk or table. Position the air tube  in  the  middle of 

your arm in line with your middle finger. 

d.  The  cuff  should  fit  comfortably,  yet  snugly  around  your  arm. 

You should be able to insert one finger between your arm and the cuff.   

Note:

   

1. 

Please refer to the cuff circumference range in 

“SPECIFICATIONS” to make 

sure that the appropriate cuff is used.   

2. 

Measuring on same arm each time. 

3. 

Do not move your arm, body, or the monitor and do not move the rubber tube 

during measurement. 

4. 

Stay still, calm for 5 minutes before blood pressure measurement. 

5. 

Please keep the cuff clean. If the cuff becomes dirty, remove it from the monitor 

and clear it by hand in a mild detergent, then rinse it thoroughly in cold water. 

Never dry the cuff in clothes dryer or iron it. Clean the cuff after the usage of 

every 200 times is recommended.   

 

5.  BODY POSTURE DURING MEASUREMENT 

 

Summary of Contents for KD-5917

Page 1: ...RIPTION 3 SPECIFICATIONS 4 NOTICE 4 SETUP AND OPERATING PROCEDURES 6 1 BATTERY LOADING 6 2 CLOCK AND DATE ADJUSTMENT 6 3 CONNECTING THE CUFF TO THE MONITOR 7 4 APPLYING THE CUFF 7 5 BODY POSTURE DURING MEASUREMENT 7 6 TAKING YOUR BLOOD PRESSURE READING 8 7 DISPLAYING STORED RESULTS 8 8 DELETING MEASUREMENTS FROM THE MEMORY 9 9 ASSESSING HIGH BLOOD PRESSURE FOR ADULTS 9 10 TROUBLESHOOTING 1 10 11 T...

Page 2: ...ht The highest value usually appears in the daytime and lowest one usually at midnight Typically the value begins to increase at around 3 00AM and reaches to highest level in the daytime while most people are awake and active Considering the above information it is recommended that you measure your blood pressure at approximately the same time each day Too frequent measurements may cause injury du...

Page 3: ...d pulse rate can be measured automatically and non invasively The LCD display will show blood pressure and pulse rate The most recent 60 measurements can be stored in the memory with date and time stamp The Electronic Blood Pressure Monitor corresponds to the below standards IEC 60601 1 2005 EN 60601 1 2006 AC 2010 Medical electrical equipment Part 1 General requirements for basic safety and essen...

Page 4: ...Environmental humidity for operation 90 RH 14 Environmental temperature for storage and transport 20 55 4 131 15 Environmental humidity for storage and transport 90 RH 16 Environmental pressure 80kPa 105kPa 17 Battery life Approx 180 times 18 All components belonging to the pressure measuring system including accessories Pump Valve LCD Cuff and Sensor Note These specifications are subject to chang...

Page 5: ...that you consult with your physician for accurate assessment There are 2 conditions under which the signal of IHB will be displayed 1 The coefficient of variation CV of pulse period 25 2 The difference of adjacent pulse period 0 14s and the number of such pulse takes more than 53 percentage of the total number of pulse 13 Please do not use the cuff other than supplied by the manufacturer otherwise...

Page 6: ...l replace all batteries with new ones Rechargeable batteries are not suitable for this monitor Remove the batteries if the monitor will not be used for a month or more to avoid relevant damage of battery leakage Avoid the battery fluid to get in your eyes If it should get in your eyes immediately rinse with plenty of clean water and contact a physician The monitor the batteries and the cuff must b...

Page 7: ...it outward away from your body and tighten it and close the Velcro fastener b Place the cuff around a bare arm 1 2cm above the elbow joint c While seated place palm upside in front of you on a flat surface such as a desk or table Position the air tube in the middle of your arm in line with your middle finger d The cuff should fit comfortably yet snugly around your arm You should be able to insert ...

Page 8: ...rily display the most recent one If no result has been stored zero will appear on LCD c Then the monitor inflates the cuff until sufficient pressure has built up for a measurement Then the monitor slowly releases air from the cuff and carries out the measurement Finally the blood pressure and pulse rate will be calculated and displayed on the LCD screen The blood pressure classification indicator ...

Page 9: ...ter three beep Press the button MEM or START the monitor will turn off 9 ASSESSING HIGH BLOOD PRESSURE FOR ADULTS The following guidelines for assessing high blood pressure without regard to age or gender have been established by the World Health Organization WHO Please note that other factors e g diabetes obesity smoking etc need to be taken into consideration Consult with your physician for accu...

Page 10: ...onitor 11 TROUBLESHOOTING 2 PROBLEM POSSIBLE CAUSE SOLUTION LCD Display shows EE The cuff was not properly applied or the rubber tube was bent or pressed Review the cuff applying and testing sections of the instructions and re test LCD Display shows abnormal result The cuff position was not correct or it was not properly tightened Apply the cuff correctly and try again Body posture was not correct...

Page 11: ...riately qualified technical personnel to repair those parts of equipment which are designated repairably can be supplied 9 The monitor can maintain the safety and performance characteristics for a minimum of 10 000 measurements or three years and the cuff integrity is maintained after 1 000 open close cycles of the closure 10 It is recommended the cuff should be disinfected 2 times every week if n...

Page 12: ...ufacture s declaration electromagnetic emissions The KD 5917 is intended for use in the electromagnetic environment specified below The customer or the user of the KD 5917 should assure that it is used in such an environment Emissions test Compliance Electromagnetic environment guidance RF emissions CISPR 11 Group 1 The KD 5917 uses RF energy only for its internal function Therefore its RF emissio...

Page 13: ...e at least 30 Power frequency 50 60 Hz magnetic field IEC 61000 4 8 3 A m 3 A m Power frequency magnetic fields should be at levels characteristic of a typical location in a typical commercial or hospital environment Table 3 For ME EQUIPMENT and ME SYSTEMS that are not LIFE SUPPORTING Guidance and manufacturer s declaration electromagnetic immunity The KD 5917 is intended for use in the electromag...

Page 14: ...tion is affected by absorption and reflection from structures objects and people a Field strengths from fixed transmitters such as base stations for radio cellular cordless telephones and land mobile radios amateur radio AM and FM radio broadcast and TV broadcast cannot be predicted theoretically with accuracy To assess the electromagnetic environment due to fixed RF transmitters an electromagneti...

Page 15: ...eparation distance according to frequency of transmitter m 150 kHz to 80 MHz 80 MHz to 800 MHz 800 MHz to 2 5 GHz 0 01 0 12 0 12 0 23 0 1 0 38 0 38 0 73 1 1 2 1 2 2 3 10 3 8 3 8 7 3 100 12 12 23 For transmitters rated at a maximum output power not listed above the recommended separation distance d in meters m can be determined using the equation applicable to the frequency of the transmitter where...

Reviews: