background image

E1 Single Speed Electric Motor Unit, 12V & 24V 

To Suit Self-Tailing Winch Sizes 58,62

p12

TROUBLESHOOTING

E1 IN-BUILT SYSTEM PROTECTION

The E1 Electric Motor Unit has a very high level of in-built system protection, via monitoring of 
various operating parameters, its integrated controller and other protection/control componentry.

This functionality includes:

•  Reverse polarity protection 
•  Mechanical overload protection 
•  System low voltage detection 
•  Thermal overload protection 
•  Continuous run time limiting
•  Accidental start protection 

REVERSE POLARITY PROTECTION

If the motor unit is inadvertently connected to the power system with reversed polarity the motor’s 
internal fuse will blow. The fuse will have to be replaced before the motor will start again.

To replace the fuse:

•  Remove the cable ties that secure the control cable to the outside of motor cover.
•  Remove the two screws from the end of the outer motor cover (using a #1 Phillips head 

 

screw driver) - refer to picture below.

•  Rotate the outer motor outer cover slightly and carefully pull the motor cover away from the 

motor unit. Note: After the first 5mm (3/16”) the O-ring will release the cover, there will be no 

resistance the rest of the way, and very little force should be used so as not to damage the 
internal wiring connections. 

•  When the outer cover is clear of the internal components, set it to one side so that there is 

 

no tension on the internal control cable wires.

•  Replace the 5A glass fuse, located on the PCB as shown below.
•  Reassemble in reverse order. Make sure that the internal cables are not wedged between the 

cover and internal components and again that no force should be required to replace the cover 
until the O-ring is reached. Before pushing the cover on the final few millimetres over the O-ring, 
make sure that the screw holes in the outer cover are aligned with the threaded rods inside. 
Refer to picture below for threaded rod position.

Motor outer cover 

attachment screws

Threaded rods for

motor outer cover 

attachment  screws

5A Glass Fuse

PCB location

Summary of Contents for 58 ST E1

Page 1: ...V To Suit Self Tailing Winch Sizes 58 62 RON WPM 710479 E1 58 62ST Rev 4 FOR USE WITH Serial No PS______________________ Winch versions 58 V 1 0 62 V 1 0 RA2058011300 RA2058011400 RA2058211300 RA20582...

Page 2: ...______________________________________ 4 Parts list________________________________________________________ 5 Installation instructions_____________________________________ 6 10 Wire circuit breaker b...

Page 3: ...eration is always possible by simply inserting a standard winch handle Included in your E1 Electric Motor Kit Motor unit Gear wheel 4 Push button incl 500 mm 19 5 8 control cable A1 Push button Gasket...

Page 4: ...is gear wheel will already be fitted inside the winch The gear wheel has a hexagonal section that protrudes from the winch base to engage in the motor unit drive shaft When supplied as an E1 Electric...

Page 5: ...00 23 1 Ratchet gear 775860 24 1 Key DIN6885 A4x7x20 25 9 Screw DIN912 A4 M6x25 26 4 Screw DIN933 A4 M6x20 27 1 Key DIN6885 A4 5x5x16 A1 1 Push button with plastic cover RA582000 A2 1 Push button gask...

Page 6: ...ase on the motor unit in the various positions prior to installation can assist with visualising the motor position options Note To ensure the correct functioning of the winch it should be positioned...

Page 7: ...that the motor is aligned properly The protruding octagonal detail on the drive shaft housing 15 flange must fit snugly into the octagonal recess in the winch base to allow the motor top flange to fit...

Page 8: ...ence the winch Product Manual during this process After removing the self tailing arm and drum Remove the drive shaft from the winch by placing a locking winch handle into the socket at the top of the...

Page 9: ...r tube Or drill a 25mm 1 hole at a 2mm offset to the centre of the push button location Refer to the push button drilling diagram below Using the supplied push button gasket A2 as a template drill 3 x...

Page 10: ...up current spike WARNING Do not use smaller wire than recommended in the table This can cause malfunction of the winch and in worst case FIRE The wires should always be as short as possible 12V DC 24...

Page 11: ...rnal fuse will blow and need to be replaced See page 12 for instructions WARNING PUSH BUTTON Push button cable 1 Blue Switch 3 Blue Black Ground 4 Red LED STANDARD CONNECTION PUSH BUTTON CABLE MOTOR C...

Page 12: ...r using a 1 Phillips head screw driver refer to picture below Rotate the outer motor outer cover slightly and carefully pull the motor cover away from the motor unit Note After the first 5mm 3 16 the...

Page 13: ...e comes back above 11 0 Volts for 12V systems and 22 Volts for 24V systems 3 Flashes Max temperature of the motor has been reached The motor has overheated Status will automatically reset to normal an...

Page 14: ...ing of internal parts To avoid potential sea water ingress and to maximise the service life of your electric winch motor unit it is recommended to re lubricate the motor unit drive shaft Sealing Ring...

Page 15: ...4 1 2 122mm 4 13 16 266mm 10 1 2 213mm 8 3 8 41mm 1 5 8 MOTOR OFFSET Minimum Ox 334mm 13 3 16 Oy 180mm 7 1 16 Minimum Oy 121mm 4 3 4 Ox 370mm 14 9 16 Values with motor in optimum position to minimise...

Page 16: ...Sizes 58 62 p16 DRILLING TEMPLATE SIZE 58 62 NOT TO SCALE PART NO RD100214 DRILLING TEMPLATE ANDERSEN 58 62 ST E1 60 200mm 6 3 32 29mm 66mm BASE PLATE 230mm 7 3 32 39 7mm HOLE 10 5mm 13 32 6 OFF Self...

Page 17: ...ied to operate an electric winch must be kept at a safe distance from the winch and any rigging or fittings that are under load Long hair and or loose clothing must be tied back to avoid being caught...

Page 18: ...isit www andersenwinches com Visit www andersenwinches com WORLDWIDE DISTRIBUTION SERVICE WARRANTY E1 Single Speed Electric Motor Unit 12V 24V To Suit Self Tailing Winch Sizes 58 62 p18 PRODUCT MANUAL...

Reviews: