background image

 

 
 

 

TPAD10M RFID Pad Reader 

 

User Manual 

 
 
 
 
 
 
 

 

 

 

Before you use this product, please carefully read this manual, and properly keep 

it for future reference. 

 

As  our  products  continue  improving,  they  may  be  changed  without  advanced 

notice. 

 

The contents of this manual have been carefully checked. For any printing error or 

misunderstanding content, please contact us as soon as possible. 

 

Version: V1.00 

Summary of Contents for TPAD10M

Page 1: ...s manual and properly keep it for future reference As our products continue improving they may be changed without advanced notice The contents of this manual have been carefully checked For any printi...

Page 2: ...mmunication Interface 4 2 5 Power Switch 4 3 Device Connection 5 4 Description Of Indicator Light 5 5 Instructions Of Configuration Tools 6 5 1 Configuration Description Of Parameters 7 5 1 1 Communic...

Page 3: ...It can be widely used in book file management jewelry inventory medicine management store counter settlement and other fields 1 2 Product Features Support ISO15693 ISO18000 3M1 ISO14443A ISO18000 3M3...

Page 4: ...Power 0 2W Communication Interface USB Recognition Distance ISO 14443A 15cm ISO 15693 24cm Range Of Reading Within Agreed Area 1cm Voltage 5VDC USB powered Maximum Power Consumption 1W Metal Shielding...

Page 5: ...cs Technology Co Ltd 3 16 http www gzandea com 2 Product Structure 2 1 Product Appearance Figure 1 Product appearance description Table 2 Product appearance description No Description Power switch USB...

Page 6: ...ension 2 3 Hardware Interface Description 2 4 Communication Interface Communication interface of the device adopts USB interface and it can connect directly through the computer USB interface as shown...

Page 7: ...om Figure 4 Power switch 3 Device Connection The device is connected to the PC via a USB communication interface and power is supplied via USB without additional power supply Figure 5 Connect via the...

Page 8: ...Of Configuration Tools Please refer to Section 3 Device Connection to connect the device After the device is connected press the power button When making sure that the device is normally powered by o...

Page 9: ...ices list as follows Figure 8 Connection steps As shown above Step click the Start button to enter the main interface of the test software 5 1 Configuration Description Of Parameters After the softwar...

Page 10: ...http www gzandea com Figure 9 Parameter configuration interface 5 1 1 Communication Interface Figure 10 Configuration interface for communication interface Bus address between 1 255 Baud Rate 9600 19...

Page 11: ...quency value range from 0 to 255 only applicable for the Flash type Active time the frequency of buzzer only applicable for the Flash type 5 1 3 RF Parameters Figure 12 Configuration interface for RF...

Page 12: ...3 ISO18000p3m3 Enable to count tags of ISO18000p3m3 air protocol 4 ISO14443B Enable to count tags of ISO14443B air protocol ISO15693 1 Data coding 1 4 1 256 2 Subcarrier single negative carrier double...

Page 13: ...tenna sensing area 4 Stop Trigger Try N times when no tags set the number of attempts if no new tags are found Max Timeout set the time of stopping trigger due to timeout ISO15693 1 AFI 00 FF Note 00...

Page 14: ...end commands scan setting in the scan mode should be configured in advance Scan Mode Configuration 1 Filtered time of duplicated tag sec The tag can only be counted again after leaving for the specifi...

Page 15: ...a complete UID 4 Parameter of reading block with ISO15693 Byte offset The offset of the first byte to be read Byte count The number of bytes to be read Note The above configuration is a common config...

Page 16: ...t the procedure as shown in the following figure and for tags test Figure 16 Single tag operation test steps Note Step 1 In the software main interface select the menu Single Tag Test Step 2 In the Si...

Page 17: ...ed in green indicating that it can be operated 2 Click Read Block to read the data value of the data block selected in step 1 3 Write the value in the line green area of the data block whose value sho...

Page 18: ...est susceptible d en compromettre le fonctionnement NOTE This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These lim...

Page 19: ...y Co Ltd Address Room 401 Building H Jingye San Street Yushu Industrial Park Economic And Technological Development Zone Guangzhou Zip code 510663 Phone 0086 20 32039550 32039551 32039552 Fax 0086 20...

Reviews: