background image

 

User manual 

Guangzhou Andea Electronics Technology Co., Ltd.                                                          9/15 
http://www.gzandea.com                   

5.1.5.

 

System Work Mode 

 

Figure 10

 

Configuration interface for system work mode 

 

Mode: 

1) Host mode: the host software needs to send commands. 

2) Scan mode: the inventory can be automatically completed, even if the host 

software does not send commands; scan setting in the scan mode should be 

configured in advance. 

 

Scan Mode Configuration: 

1) Filtered time of duplicated tag(sec): The tag can only be counted again after 

leaving the specified time. 

2) Port of data output: Uart1 output, USBHID output, virtual keyboard output, 

Wiegand 26, Wiegand 34. 

3) Scan option 

  Output UID: output the tag UID. 

  Output block’s data: output the content of the data block (not including the 

security status byte). 

  Output format of block’s data: 

      A. Format as hex string. 

      B. Format as ASCII. 

Summary of Contents for RL863

Page 1: ...please read this manual carefully and properly keep it for future reference As our products continue improving they may be changed without advanced notice The copyright of this manual belongs to our c...

Page 2: ...Version V1 3...

Page 3: ...Connection 3 5 Instructions Of Configuration Tools 4 5 1 Configuration Description Of Parameters 5 5 1 1 Communication Interface 5 5 1 2 Buzzer Default Parameters 6 5 1 3 RF Parameters 6 5 1 4 Invent...

Page 4: ...same time This product is widely used in desktop card issuance access control systems electronic bills libraries finance and other fields 1 2 Product Features Operating frequency 13 56MHz Support ISO...

Page 5: ...tion Distance ISO 15693 16 cm ISO14443A 10 cm ISO 18000 3M3 6 cm Communication Interface USB Voltage 5V USB powered Maximum Power 0 65W Standard Sizes 105 70 10mm Maximum Operating Temperature 35 2 Ha...

Page 6: ...Figure 1 Communication interface 3 Product Dimension The external dimensions of the product are shown in the following figure unit mm Figure 2 Product dimension 4 Device Connection Before using the r...

Page 7: ...ick this file to open the configuration tool as shown below Figure 4 R Tool connection interface Select the corresponding communication method according to the actual interface type used by the device...

Page 8: ...ove Step click the Start button to enter the main interface of the test software 5 1 Configuration Description Of Parameters 5 1 1 Communication Interface Figure 6 Configuration interface for communic...

Page 9: ...quency value range from 0 to 255 only applicable for the Flash type Active time the frequency of buzzer only applicable for the Flash type 5 1 3 RF Parameters Figure 8 Configuration interface for RF p...

Page 10: ...3 ISO18000p3m3 Enable to count tags of ISO18000p3m3 air protocol 4 ISO14443B Enable to count tags of ISO14443B air protocol ISO15693 1 Data coding 1 4 1 256 2 Subcarrier single negative carrier double...

Page 11: ...enna sensing area 4 Stop Trigger Try N times when no tags set the number of attempts if no new tags are found Max Timeout set the time of stopping trigger due to timeout ISO15693 1 AFI 00 FF Note 00 m...

Page 12: ...send commands scan setting in the scan mode should be configured in advance Scan Mode Configuration 1 Filtered time of duplicated tag sec The tag can only be counted again after leaving the specified...

Page 13: ...a complete UID 4 Parameter of reading block with ISO15693 Byte offset The offset of the first byte to be read Byte count The number of bytes to be read Note The above configuration is a common config...

Page 14: ...t the procedure as shown in the following figure and for tags test Figure 12 Single tag operation test steps Note Step 1 In the software main interface select the menu Single Tag Test Step 2 In the Si...

Page 15: ...he data value of the data block selected in step 1 3 Write the value in the line green area of the data block whose value should be written and then click Write Block 4 After the operation is complete...

Page 16: ...e device has poor contact Troubleshooting method Please check whether the tag is damaged and take another tag to test If the new tag can be read normally it means that the tag is damaged if the tag st...

Page 17: ...est susceptible d en compromettre le fonctionnement NOTE This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These lim...

Page 18: ...gy Co Ltd Address Room 401 Building H Jingye San Street Yushu Industrial Park Economic And Technological Development Zone Guangzhou Zip code 510663 Phone 86 020 32039550 32039551 32039552 Fax 86 020 3...

Reviews: