  The device is designed for use on adults only, not newborns or infants. 

  Environment for use: The device is for use in the home healthcare environment. 

  This device is designed to measure blood pressure and pulse rate of people for 

diagnosis. 

 
 

Precautions 

  Precision components are used in the construction of this device. Extremes in 

temperature, humidity, direct sunlight, shock or dust should be avoided. 

  Clean the device and cuff with a dry, soft cloth or a cloth dampened with water 

and a neutral detergent. Never use alcohol, benzene, thinner or other harsh 

chemicals to clean the device or cuff. 

  Avoid tightly folding the cuff or storing the hose tightly twisted for long periods, as 

such treatment may shorten the life of the components. 

  The device and cuff are not water-resistant. Prevent rain, sweat and water from 

soiling the device and cuff. 

  Measurements may be distorted if the device is used close to televisions, 

microwave ovens, cellular telephones, X-ray or other devices with strong 

electrical fields. 

  Used equipment, parts and batteries are not treated as ordinary household 

waste, and must be disposed of according to the applicable local regulations. 

  When reusing the device, confirm that the device is clean. 

  Do not modify the device. It may cause accidents or damage to the device. 

  To measure blood pressure, the arm must be squeezed by the cuff hard enough 

to temporarily stop blood flow through the artery. This may cause pain, numbness 

or a temporary red mark to the arm. This condition will appear especially when 

measurement is repeated successively. Any pain, numbness, or red marks will 

disappear with time. 

Contraindications 

The following are precautions for proper use of the device. 

  Do not apply the cuff on an arm with another medical electrical equipment 

attached. The equipment may not function properly. 

 

People who have a severe circulatory deficit in the arm must consult a doctor 

before using the device, to avoid medical problems. 

 

Do not self-diagnose the measurement results and start treatment by yourself. 

Always consult your doctor for evaluation of the results and treatment. 

 

Do not apply the cuff on an arm with an unhealed wound. 

 

Do not apply the cuff on an arm receiving an intravenous drip or blood 

transfusion. It may cause injury or accidents. 

 

Do not use the device where flammable gases such as anesthetic gases are 

present. It may cause an explosion. 

 

Do not use the device in highly concentrated oxygen environments, such as a 

high-pressure oxygen chamber or an oxygen tent. It may cause a fire or explosion. 

 

  

Summary of Contents for UA-705

Page 1: ...Digital Blood Pressure Monitor Model UA 705 Instruction Manual Original Manuel d instructions Traduction Manual de Instrucciones Traducción Manuale di Istruzioni Traduzione 使用手冊 翻譯 1WMPD4000988D ...

Page 2: ...e 10 What Is Hypertension And How Is It Controlled 11 Why Measure Blood Pressure At Home 11 WHO Blood Pressure Classification 11 Blood Pressure Variations 11 Troubleshooting 12 Maintenance 12 Technical Data 13 Dear Customers Congratulations on purchasing a state of the art A D blood pressure monitor one of the most advanced monitors available today Designed for ease of use and accuracy this device...

Page 3: ... reusing the device confirm that the device is clean Do not modify the device It may cause accidents or damage to the device To measure blood pressure the arm must be squeezed by the cuff hard enough to temporarily stop blood flow through the artery This may cause pain numbness or a temporary red mark to the arm This condition will appear especially when measurement is repeated successively Any pa...

Page 4: ... connector plug Battery LR6P R6 or AA Air hose Artery position mark Arm cuff Heart mark Systolic pressure Diastolic pressure Pulse rate Exhaust mark Exhaust air from the cuff Pressure mark Pump air into the cuff Battery indicator I H B indicator Irregular heartbeat indicator Pressure Bar Indicator and WHO Classification Indicator MEMORY Part Of Display ...

Page 5: ...exhaust valve button to exhaust air from the cuff Flashes when pressure is insufficient for the measurement Pump air into the cuff with the rubber bulb Previous measurements stored in memory FullBattery Indicates remaining battery power lowBattery Blinks when battery is low Replace battery with new one when the indicator blinks Unstable blood pressure due to movement during the measurement Try the...

Page 6: ...e device will not work When LOW BATTERY mark blinks in the display replace the battery with a new one LOWBATTERYmark does not appear when the battery is drained Battery life varies with the ambient temperature and may be shorter at low temperatures Use the specified battery only The battery provided with the device is for testing monitor performance and may have a limited life Remove the battery i...

Page 7: ...to 32 cm Adult cuff CUF D A Arm size The circumference at the biceps Note Model UA 705 is not designed for using a small adult cuff Symbols printed on the cuff Symbols Function Meaning Recommended Action Artery position mark Set the mark on the artery of the upper arm or in line with the ring finger on the inside of the arm Index REF Catalog number Proper fit range for the adult cuff It s printed ...

Page 8: ...asurement Do not measure immediately after physical exercise or a bath Rest for twenty or thirty minutes before taking the measurement Try to measure your blood pressure at the same time every day Measurement Operation During measurement it is normal for the cuff to feel very tight Select a measurement mode operation of the device Normal measurement with storing data Press the START button Recalli...

Page 9: ...s the exhaust valve button to expel the air from the cuff 4 When inflation is complete deflation starts automatically and the buzzer sounds and the heart mark blinks indicating that the measurement is in progress Once the pulse is detected the mark flashes and the buzzer sounds with each pulse beat 5 When the measurement is complete the buzzer sounds and the mark is displayed The systolic and dias...

Page 10: ...ure varies constantly depending on what you are doing and what you have eaten What you drink can have a very strong and rapid effect on your blood pressure This device bases its measurements on the heartbeat If you have a very weak or irregular heartbeat the device may have difficulty determining your blood pressure Should the device detect a condition that is abnormal it will stop the measurement...

Page 11: ...ndcontactingyourphysicianifyouseethis indicatorfrequently About Blood Pressure What Is Blood Pressure Blood pressure is the force exerted by blood against the walls of the arteries Systolic pressure occurs when the heart contracts Diastolic pressure occurs when the heart expands Blood pressure is measured in millimeters of mercury mmHg One s natural blood pressure is represented by the fundamental...

Page 12: ...octor s readings and provides a more accurate complete blood pressure history WHO Blood Pressure Classification Standards to assess high blood pressure without regard to age have been established by the World Health Organization WHO as shown in the chart on the right Blood Pressure Variations An individual s blood pressure varies greatly on a daily and seasonal basis It may vary by 30 to 50 mmHg d...

Page 13: ...lood pressure The value is different from that measured at a clinic or doctor s office See Why measure blood pressure at home Other Remove the battery Re install it properly and try the measurement again Note If the actions described above do not solve the problem contact the dealer Do not attempt to open or repair this product as any attempt to do so will make your warranty invalid Maintenance Do...

Page 14: ...1 2 2007 Data memory Last 30 measurements Operating conditions 10 C to 40 C 15 RH to 85 RH 800 hPa to 1060 hPa Transport Storage conditions 10 C to 60 C 15 RH to 85 RH Dimensions Approx 81 W x 54 H x 105 D mm Weight Approx 120 g excluding battery Applied part Cuff Type BF Useful life Device 5 years when used six times a day Cuff 2 years when used six times a day Accessories sold separately Arm siz...

Page 15: ...don Business Park Abingdon Oxfordshire OX14 1DY United Kingdom Telephone 44 1235 550420 Fax 44 1235 550485 A D ENGINEERING INC 1756 Automation Parkway San Jose California 95131 U S A Telephone 1 408 263 5333 Fax 1 408 263 0119 A D AUSTRALASIA PTY LTD 32 Dew Street Thebarton South Australia 5031 AUSTRALIA Telephone 61 8 8301 8100 Fax 61 8 8352 7409 ...

Reviews: