![Anchor AF-5002 Installation & Setup Manual Download Page 13](http://html1.mh-extra.com/html/anchor/af-5002/af-5002_installation-and-setup-manual_2941139013.webp)
13
1) Position the drain saddle valve at
selected location and mark for the
opening.
2) Drill ¼-inch (6.3mm) hole at mark
through one side of pipe.
3) Remove backing from gasket and place
adhesive side to the fitting half of drain
clamp around hole.
4) Position both halves of drain saddle on
drain pipe so the opening aligns with
drilled hole. Use a small drill bit to verify
that drain clamp is properly aligned.
5) Secure drain saddle clamp on valve with
bolts and nuts provided. (Do not over
tighten, and make sure there is equal
space between saddle halves on each
side.)
6) Insert
Black tubing
to the quick fitting
connector of the saddle valve.
7) Other end of
Black Tubing
should
connect to the waste outlet of RO TFC
membrane. The connection should be to
the flow connector with black lock pin