a. Flex Line:
Loosen nut and separate the cold water riser tube
from faucet shank. Gently bend riser tube so that feed adapter
fits into faucet shank. Reinstall riser tube onto feed connector
and tighten.
b. Solid-Copper Riser Tube:
Follow same procedure as
for flex tubing above,
except cut a piece of the
riser tube so the feed
adapter can fit between
faucet and riser tube.
Note:
Use Teflon tape on feed
adapter to prevent leaks.
c. Once the feed water
adapter has been installed,
connect the
red/orange
tubing
to the feed valve.
Please see the following for flex line and solid-copper riser
installation.
2) Locate the feed-water adapter in the installation kit.