In cases of inductive load activation, as locks or magnetic lock, turnstile
’s bobbins or
collector turnstile, besides others, to avoid the return of electric current during the bobbins
shutdown, use the indicated components according the instructions below.
EN
English - 34
LOCK ACTIVATION, MAGNETIC LOCK OR INDUCTIVE LOAD
CARES
DIODE
OR
SOLENOID
Solenoid power
CATHODE
ANODE
DIODE FILTER CONNECTION SCHEME (level 1 protection - Applies to direct current
“DC”)
SOLENOID
Solenoid power
- NOTE: THERE IS NO POLARITY
SUPPRESSOR
CAPACITOR “X2 0,1uF 275V
CAPACITOR (level 1 protection - Applies to alternate current
“AC”)
CATHODE
ANODE
Solenoid power
SOLENOID
SUPPRESSOR
CAPACITOR “X2 0,1uF 275V
DIODE + CAPACITOR (level 2 protection - Applies to direct current
“DC”)
DIODE
OR
LINE FILTER FOR LOCKS
Solenoid power
SOLENOID
LINE FILTER FOR LOCKS
(level 3 protection - Applies to direct or alternate current. Filters and rectifies
the “AC” current to “DC”)