Analytic Systems PWI320 Installation & Operation Manual Download Page 7

7

Package Contents

The box should contain:

•  One PWI320 Intelligent Power Supply, 
•  One Mini-USB to Laptop cable,
•  This user guide (a pdf copy can be requested from [email protected])
•  One Warranty Registration Card. Returning this card is not mandatory for warranty 

coverage, but will assist us to stay in touch with you for updates and other news. 

Warranty registration can also be completed at www.analyticsystems.com

•  The ‘PowerWizard’ software can be downloaded from www.analyticsystems.com

If anything is damaged or missing, please contact us immediately at 1-800-668-3884 for by 

emailing [email protected]

Location and Mounting

1.  Mount the Power Supply so that the indicator LEDs and controls on the front panel are 

reasonably easy to see and access.

2.  Make sure there is at least 2 inches of clearance all around the Power Supply so that air 

can circulate through the Power Supply to keep it cool.

3.  Mount the Power Supply in a location that allows easy connection to the load. Use the 

wire gauge table and the maximum input current rating from the load to choose the 

appropriate wire gauge to connect to the Power Supply. The maximum wire gauge the DC 

output terminals can accept is AWG10 wire. 

4.  Make sure the Power Supply is protected from water. In a marine environment, install the 

optional drip shield above the Power Supply if there is any possibility of water dripping 

onto it. 

Installation

AWG

Amps

24

2

22

3

20

5

18

7

16

10

14

15

12

20

10

30

8

40

6

55

4

70

3

80

2

95

1

110

AWG

Amps

Summary of Contents for PWI320

Page 1: ...ligent Power Supply 8128 River Way Delta B C V4G 1K5 Canada T 604 946 9981 F 604 946 9983 TF 800 668 3884 US CANADA www analyticsystems com An ISO9001 and AS9100 Registered Company Battery Chargers In...

Page 2: ...Copyright 2005 2016 Analytic Systems Ware 1993 Ltd Revised April 14 2016...

Page 3: ...t to the manufacturer or an authorized service center when service or repair is required Incorrect reassembly may result in a risk of electric shock or fire Voltages in excess of 350 volts are present...

Page 4: ...e life support device or to significantly affect its safety or effectiveness Analytic Systems does not recommend the use of any of its products in direct patient care Examples of devices considered to...

Page 5: ...aterial and Finish Marine Grade Black Anodized Aluminum with 18 8 Stainless Fasteners Mounting Wall or Shelf Mount Connections Integrated Color Coded Terminal Blocks Environmental and Safety Operating...

Page 6: ...ot interfere with sensitive voice or data RF communication equipment The Power Supply is preset to the same voltage as a fully charged battery of the nominal output voltage ie 13 6V for a 12V model et...

Page 7: ...Power Supply so that the indicator LEDs and controls on the front panel are reasonably easy to see and access 2 Make sure there is at least 2 inches of clearance all around the Power Supply so that ai...

Page 8: ...ll go through a startup sequence that consists of turning the 6 LEDs controlled by the computer all Red then all Green The Power button will illuminate once the Power Supply has completely turned on I...

Page 9: ...customize the output voltage in Power Supply mode within the working range of the unit 12 0 to 15 0 volts for a 12V model scale appropriately for other output voltages Select the Active Profile and s...

Page 10: ...ly status to a monitoring system It has both a normally open and normally closed contact which changes state depending on the presence or absence of charging voltage on the output of the Power Supply...

Page 11: ...overloaded and the output voltage drops below 1 2 the nominal voltage for the unit the output will cycle on off until the overload condition is removed Power Supply Overtemp If the Power Supply gets t...

Page 12: ...common battery Power Supply terms and their definitions ABBREVIATIONS DEV Device Refers to the Power Supply Used together with the Fault LED to indicate a problem with the Device FLT Fault Used to in...

Page 13: ...13 This page intentionally left blank...

Page 14: ...14 This page intentionally left blank...

Page 15: ...c Systems reserves the right to void the warranty if a Labels identification marks or serial numbers are removed or altered in any way b Our invoice is unpaid c The defect is the result of misuse negl...

Page 16: ...Way Delta B C V4G 1K5 Canada T 604 946 9981 F 604 946 9983 TF 800 668 3884 US CANADA www analyticsystems com An ISO9001 and AS9100 Registered Company Battery Chargers Inverters Power Supplies Voltage...

Reviews: